Field Wiring Terminal Markings:
3.81mm (For Measurement Current and Communication): Use Copper Conductors Only,
wires range 16-26 AWG, torque value 3.0 lb-in.
5.08mm (For Measurement Voltage, Aux Power and Alarm Output):
Use Copper Conductors Only, wires range 12-24 AWG, torque value 7.0 lb-in.
7.62mm: Use Copper Conductors Only, wires range 12-24 AWG, torque value 4.5 lb-in.
Aux Power
Input Range
+12 ~ 48 VDC
+12 ~ 48 VDC or PoE
PoE Pin Assignments:
+ (Pin 1, 2), V- (Pin 3, 6)
Power Consumption
2 W
Dimensions (W x L x H) 127 mm x 100 mm x 33 mm
Environment
Operating Temperature -20 ~ +70 °C
Storage Temperature