9. After clicking “active board” successfully, 

the slave would wait for the master request 
message. If it shows the error message at the 
output filed, it means that master device 
doesn’t communicate with the slave device. 
Please check the master’s setting or the baud 
rate of the network 

10. If the master is communicating with this 

slave device, it shows the output value 
which was sent by the master device at the 
output filed. It means that the master can 
exchange the I/O data with the slave device. 

11. After communicating with the master device, 

the user can press the check-box to change the 
input data of the slave device. The users can 
find out that the input value in the master site 
is changing synchronous. 

12. When the master is communicating with 

this slave device, the user can change the 
output value in the master site. The user 
would find out that the output value in the 
output filed is changing synchronously in 
the output filed of the slave. 

Summary of Contents for PISO-DNS100U

Page 1: ...ould help you quickly to familiarize yourself with the PISO DNS100U PCI board and DeviceNet communication For more the detail information please refer to the user s manual of the PISO DNS100U Here is...

Page 2: ...ed on the commands of exchanging information and I O data To establish slave server mechanism there are four main steps to be followed The figure demonstrates the basic process for the DeviceNet commu...

Page 3: ...the users how to connect the master and slave devices by CAN bus The slave devices should be connected to form the serial type which is shown as follows The following wire connection is wrong which i...

Page 4: ...duplicate MAC ID in the DeviceNet network 3 ON OFF This indicates that the firmware is working All slave devices in the PISO DNS100U are communicating with the master successfully 4 ON ON This indicat...

Page 5: ...ftware in the path of devicenet slave piso dns100 in the Fieldbus_CD or from ftp ftp icpdas com tw pub cd fieldbus_cd devicenet slave piso dns100 After installing the software the related software dem...

Page 6: ...ich the users have set Please click the ActiveBoard button to active the specific board which you have selected in the Board No field 4 Pressing Add Device button to add the slave into the EEPROM It p...

Page 7: ...n the Devices in EEPROM field PISO DNS100U Quick Start Manual Version 1 0 Jan 2010 7 8 Please click ActiveBoard button to active the specific board which you have selected in the Board ID field Note t...

Page 8: ...ws the output value which was sent by the master device at the output filed It means that the master can exchange the I O data with the slave device 11 After communicating with the master device the u...

Reviews: