Programmable Serial-to-Ethernet Device Server
PDS Series User Manual, Version 2.5, Mar. 2019
-
52 -
2.8
PDS Series Diagnostics (LED Indicator)
This section provides detailed information about the LED functions and behavior are given below.
Step 1:
Apply power (+Vs, GND) to the PDS Series module.
※
PDS(M)-700
series
power supply can range from
+10 to +30 V
DC
.
※
PPDS(M)-700-MTCP, DS-700, PPDS-700-IP67, PDS-782-25 and
PDS-5105D-MTCP
series
power supply can range from +
12 to +48 V
DC
.
Step 2:
Once power is supplied to the PDS series module, the system
LED indicator will illuminate, as follows:
ON
OFF
Unit
0.5 second
OS
M0
M1
M2
The PDS contains either Xserver or VxComm as default when shipped that is in the OS mode.
If the LED is always ON, take the following steps:
1.
Power off the module
2.
Connect the INIT* pin to the Vs+ pin
3.
Power on the module and double check the configuration