PDS-220Fx Series User Manual (V1.2, Apr. 2015)
47
Note!!
1.
The baud rate and data format settings of the client and server (PDS-220Fx #1 and
#2) are depending on COM ports of the connected device. The serial port settings can
be different between the PDS-220Fx #1 and #2.
2.
PDS-220Fx Pair-connection:
Built-in serial software buffer, baud rate and data format must
be configured on PDS-220Fx first.
3.
I
-
2541 Pair-connection:
No serial software buffer, baud rate and data format cannot be
configured on I-2541.
6. Select
“
Add COM
”
and type in the COM port of the PDS-220Fx #1 (Client) which you
want to use.
7. Type in the COM port, IP and cmd port (default: 10000) of the
PDS-220Fx #2
(Server)
, and then check the
“
Save to EEPROM
”
and click
“
submit
”
button.
8. Reboot your PDS-220Fx #1(Client) and then setting is complete.
9. Enter the configuration page of PDS-220Fx #2 (Server) web server.
10. Click the
“
COM Port Setting
”
tag to enter the settings page of PDS-220Fx #2 (Server),
and then set the Baud Rate
“
115200
”
and data format
“
8, None, 1
”
.
11. Click
“
Set Remote VCOM3 connection
”
at the PDS-220Fx #2 (Server) COM PORT
setup page.
12. Confirm that the Local COM port/Remote COM port field of the PDS-220Fx #2 (Server)
is “
None
”.
5
6
7