Step 8:
Calibrate the Analog Input Channel 4 to 4.9V
(1)
Connect 4.9 V voltage source to PCIe-LM4.CON1.AI4+ (Pin14)
(2)
Connect GND source to PCIe-LM4.CON1.AI4- (Pin48)
(3)
Click CH4 Rate Group 0
“Read”
button to get hexadecimal value.
(4)
Click CH4 Rate Group 1
“Read”
button to get hexadecimal value.
(5)
Click CH4 Rate Group 2
“Read”
button to get hexadecimal value.