M-7084 User Manual, Rev. A1.3 7PH-013-A13
76
Examples:
Command: @01BB
Response: !013A
Reads the battery backup counter status for module 01
and returns a response of 3A, meaning that battery
backup counter for channels 1, 3, 4, and 5 are enabled
and disabled for all other channels.
Related Commands:
Section 2.25 @AABBVV
Note:
The command is not available to the channels that are set to
type code 51, frequency measurement.