A.5 Automatic Home Search
Home search is often used when the machine was first opened or the system was
occurred the alarm or error signal. Both of two above situations, user can take the home
search motion to let the machine return the operation origin.
I-8092F provide the functions that automatically executes a home search sequence such
as high-speed near home search
→
low-speed home search
→
encoder Z-phase
search
→
offset driving without CPU intervention. Users should dispose the hardware signals
as the same as the below figure. The figure shown below illustrates the example of 1-axis
driving system. 2 axes can be assigned in the same way.
Fig. A-29 X-axis hardware signal disposition