Input Channels
2 (Sink/Source)
Type
Isolated Open Collector (Sink)
Max. Load Current
100 mA/channel
Load Voltage
+5 VDC to +30 VDC
Response speed
5K Hz/s
LED Indicators/Display
System LED Indicator
1 LED as Power/Communication Indicator
I/O LED Indicator
4 LEDs as Digital Input & Digital Output
Isolation
Intra-module Isolation, Field-to-Logic
2500 VDC
EMS Protection
ESD (IEC 61000-4-2)
±4 kV Contact for Each Terminal
±8 kV Air for Random Point
Power
Power Consumption
1.8 W Max.
Environment
Operating Temperature
-25 to +75°C
Storage Temperature
-30 to +80°C
Humidity
5 to 95% RH, Non-condensing
Mechanical
Dimensions (W x L x H)
30 mm x 102 mm x 115 mm