Example:
Command (
ASCII
): 99$P1140400000000FFFFFFFF00
Command (
HEX
): 39 39 24 50 31 31 34 30 34 30 30 30 30 30 30 30 30
46 46 46 46 46 46 46 46 30 30
Response: OK
Set the setting of CAN specification=2.0A, CAN baud rate= 125 Kbps,
acceptance code=00000000, acceptance mask=FFFFFFFF, disable
error response, disable timestamp response into the I-7540D and the
7540D response “OK” command to mean that the configuration of CAN
has been changed.
Note:
This command can only be accepted by 7540D’s port
10000