I-7530 RS-232/CAN Converter User’s Manual (Version 2.5, Mar/2012) ------------- 29
¾
Example:
Command: T2E88<CR>
Send a CAN message with a standard remote frame. ID=2E8,
DLC=8.
4.3 eIIIIIIIILDD…[CHK]<CR>
Description:
Send or receive an extended CAN data frame.
¾
Syntax: eIIIIIIIILDD…[CHK]<CR>
e
Stands for the extended (2.0B) data frame.
IIIIIIII
29 bits Identifier (00000000~1FFFFFFF)
L
Data length (0~8)
DD…
Input data frame value according to the data length
(00~FF)
¾
Response:
Valid command: No response
Invalid command: ?<Error Code><CR>
¾
Note:
It is necessary to enable the “Error Response” function in the I-
7530 Utility, in order to receive Syntax and/or communication error
information at the host PC.
¾
Example:
Command: e1234567851122334455<CR>
Send a CAN message with an extended data frame. ID=12345678,
DLC=5, data1=11, data2=22, data3=33, data4=44 and data5=55.
4.4 EIIIIIIIIL[CHK]<CR>
Description:
Send or receive an extended CAN remote frame.
¾
Syntax: EIIIIIIIIL[CHK]<CR>
E
Stands for the extended (2.0B) CAN remote frame.
IIIIIIII
29 bits Identifier (00000000~1FFFFFFF)
L
Data length (0~8)