I-7188XA Series User’s Manual ( Ver1.2, Feb/2014, 7MH-019-10 ) ---
71
4.11 Using Digital Input and Digital output
The I-7188XA(D) provides 2 DI channels and 2 DO channels. The
SetDo1On()
,
SetDo1Off()
,
SetDo2On()
and
SetDo2Off()
functions can
be used to control the two DO channels, and the
GetDi1()
and
GetDi2()
functions can be used to read the states of the two DI channels.
For DI and DO wiring information, please refer to
Section 1.4.6 DI and
DO Wire Connection
.
The wiring for a DO application is as follows:
DO1
DO2
DI1
DI2
TXD4
RXD4
GND
TXD3
RXD3
INIT*
D2+
D2-
Vs+
GND