12
Q5: If I forget the IP address of the EIP-2000 modules, how do I search them?
A5: Users can return to the factory default. Please select to the FW mode then reboot.
Connect to the EIP module with Ethernet cable directly. The EIP-2000 module factory default value is
Parameters
Factory Default Value
IP
192.168.255.1
Subnet Mask
255.255.0.0
Gateway
192.168.0.1
Please set the IP address in 192.168.255.xx, then scan the module with the EIP-2000 Utility.
Q6: I can't update the firmware with the Utility, how should I do?
A6: Please try the following tips,
(1) Disable the firewall and anti-virus.
(2) Connect the module directly without Ethernet switch.
(3) Disable the Wi-Fi adapters and any other Ethernet interfaces.
(4) The firmware file (.dat file) is saved in the path that includes illegal characters, for example, “/_.)&-
+!...”, space, Chinese, etc.
(5) The IP address of PC (laptop) is not in the same network area of the module. (The IP address of
PC must be the same with the factory settings of EIP modules)
Q7: How to know the version of EIP-2000 modules hardware?
A7: There is a mark on the front side of the case to distinguish non-RevB and RevB.
The case with “RevB” means the RevB version, and empty means “non-RevB” version.