background image

 

 

                   

 

Install

 CAN Slave Utility 

 

Step1:

Download the CAN Slave Utility setup file from the web site 

   

 

 

 

http://www.icpdas.com/download/index.htm

   

or CD-ROM disk following the path: 

“/CANopen/Slave/CAN-8x23/Utility/Setup.exe” 

Step 2:

 

Execute the CAN_SL_Setup.exe file to install the CAN Slave Utility. 

 

CAN-8123/ CAN-8223 Configuration (Off-line mode) 

Step 1:

 

Select “Application Layer” to “CANopen”. Then, select the “Setting status” to offline.

 

Here, assume that users’ CAN slave device is CAN-8223 with node id 123 and baud rate 

1000Kbps. Fill the correct value of users’ CAN-8223 node id and baud in the “NODE ID” and 

“CAN Baud rate” filed. Then, select the “Slot Number” to “2 Slot”. 

 

 

Step 2:

 

Assume that users plug the I-8024 and I-8042 slot modules in the slot 0 and 1 

respectively. Click the slot 0 icons shown in the “CAN Slave Device Situation” frame. Select 

CAN-8123/CAN-8223/CAN-8423 Quick Start User Guide (Version 2.0 July/2007)  --------- 

 3 

Summary of Contents for CAN-8123

Page 1: ...nstructions For more detail information about the CAN 8123 CAN 8223 CAN 8423 please refer to the CAN 8123 CAN 8223 CAN 8423 user manual in the product CD or download it from following web site http ww...

Page 2: ...nnect it directly with any other standard male 5 pin screw terminal Take a note that the CAN 8423 power pin of CAN connector is useless Therefore users need to give CAN 8423 power by using power conne...

Page 3: ...lication Layer to CANopen Then select the Setting status to offline Here assume that users CAN slave device is CAN 8223 with node id 123 and baud rate 1000Kbps Fill the correct value of users CAN 8223...

Page 4: ...re configured click Save Setting to go on the next Step 3 Users can check the default settings for each slot module by clicking this module Or move the mouse pointer on the slot module to see the modu...

Page 5: ...utput range settings by using CANopen SDO protocol For more detail please refer to the section 5 5 in CAN 8123 CAN 8223 CAN 8423 user manual CAN 8423 Configuration On line mode Before using the CAN Sl...

Page 6: ...7 Rotary Switch Value Baud rate K BPS 0 10 1 20 2 50 3 125 4 250 5 500 6 800 7 1000 Step 3 Execute the CAN_SL exe file and the figure will be displayed Select a PC COM port to connect the CAN 8423 Her...

Page 7: ...users select the output range of one channel Click Set button to store the parameter setting If all of slot module configurations are finished click Build EDS File button to go on the next step Step...

Page 8: ...resistance Configure the CAN 8123 CAN 8223 CAN 8423 by using off line mode Configure the CAN 8423 by using on line mode Set the CAN 8123 CAN 8223 CAN 8423 terminal resistance Power off the CAN 8423 S...

Reviews: