background image

Unboxing

We strongly recommend keeping the original packaging of your 

unit for as long as your warranty lasts. It can  be used if you ever 

re-locate the pool and offers you peace of mind for transport.

To unpack, unscrew the bolts from  the wooden crate starting 

from the top panel, then the sides. First thing to note is to make 

sure nothing is missing. 

Requirements of the room

Prior to using your Mipod, you must ensure that the area of 

the room where the Mipod is installed should not be less than 

6 Square Meters (65 Square Feet) for best results. The door 

frames should be at least 810mm wide (32 inches) to allow the 

Mipod to be easily carried inside.  

Extreme Weather Exposure

For best results,  the ambient room temperature recommended 

for all models should be between 10-25ºC (50º-77ºF). 

If  using your MiPod in extreme cold temperatures, 

never

 allow 

the water to freeze or serious damage could occur that is not 

covered under warranty. If freezing conditions are expected in 

the room where the MiPod is installed, empty the water, add 

anti-freeze to the water or turn on the heating mode if your 

model has that function to keep water above freezing. 

On very hot climates over 45ºC, it may not be possible to 

run the system at full power due to the excessive heat. If the 

temperature inside the unit exceeds 70ºC, the over heat safety 

circuit will operate and shut the machine down. 

Prepare for set up

Positioning

Your MiPod pool must be placed on a uniformly flat and level surface. 

Be sure to place the pool on an area that can support the weight of 

the bath when full (water is very heavy, 1KG per Litre).  It is always 

recommended that you seek the advice of a qualified engineer or 

the local council if unsure. If eventual servicing is required for any 

particular reasons, please also make sure that you have easy access 

to all side vents and panels. We suggest that you closely consider the 

required location for your ice bath prior to filling your bath. Please 

account for the attachment point to drain the surplus water. We also 

recommend to have a floor drain nearby for easy drainage of your 

pool.

Airflow

For models with internal chillers, please ensure your MiPod is 

placed at a minimum distance of 300mm on all sides away from any 

obstacle, wall or structure to allow proper airflow. Please also make 

sure it is kept away from heat sources of any description. 

You 

must

 provide appropriate ventilation to keep the machine within 

a safe operating temperature. A good ventilated area is required so 

your chiller can disperse the heat effectively into the air and it should 

not be placed in a confined space otherwise it will reach unsafe 

temperatures that will cause the inbuilt safety system to operate and 

shut down the unit. 

Water Condensation 

Please note that your unit is a very powerful chiller and 

condensation will occur inside of your machine and you may notice 

a small amount of water at the base. Condensation is water from 

the air being condensed as ice or water on the very cold surfaces of 

the iCool’s machinery. This is more evident in high humidity where 

the air contains a lot of water.  

Minimum 300mm

W

ALL or 

OBS

TRUCTION

WALL or OBSTRUCTION

Min. 

300mm

Minimum 300mm

Min. 300mm

To make setup as smooth as possible, please follow 

carefully the instructions outlined below. Do not start 

your MiPod until you have read this entire owner’s 

manual. Improper installation or operation may result 

in equipment damage not covered by warranty.  

Summary of Contents for 2 Series

Page 1: ...Series 2 Owner s Manual MiPod Range www icoolsport com support icoolsport com ...

Page 2: ......

Page 3: ...O1 Your MiPod O2 Quick Set Up O3 Get Started O4 Safety Procedures O5 Technical Support Table of contents ...

Page 4: ...Your MiPod O1 ...

Page 5: ...eir own being the most technically advanced and the most powerful chilling systems of any comparable product available on the market They give you the fastest chilling performance available anywhere Manufactured from the highest quality materials and components for long service life ice bath sessions are quick to set up and easy to use What s new in Series 2 Wide Range Our large range offers fully...

Page 6: ...n the voltage sticker is located inside the Electronic box right below the Main Switch Included with your MiPod This manual is intended to help you get started using the MiPod Range of all in one products To know your device s features specifications and operation instructions you will first need to identify your product Below are some guidelines to help you determine your model your series and yo...

Page 7: ...ls Control Weight MiPod Chill 220V AC Single phase 50 60Hz 5000W 2000W 350g Hychill Minus 40 15 Amp 30mA 3 Pin heavy duty with Earth Pool Grade GRP Marine Grade Alumnium Remote 13inch Touch Screen 90Kg Empty MiPod Series with Internal Heat Pump support icoolsport com Made in Australia FrontView Left SideView Right SideView Componentscomplywith Compact Series4 MadeinAustralia IC22000 On Off 6 1 7 6...

Page 8: ...om 25ºC down to 5ºC Please note the time taken each time depends on many variables the amount of water the surrounding room temperature the ventilation of your machine the initial water temperature Leave the unit Always On so you can enjoy an ice bath anytime you want ...

Page 9: ...can be connected to any unit from our Portable chillers range Must be ordered at the same time as custom water connections are pre fitted in the factory Installation recommended to be completed by a certified plumber ...

Page 10: ...Quick Setup O2 ...

Page 11: ...ed that you seek the advice of a qualified engineer or the local council if unsure If eventual servicing is required for any particular reasons please also make sure that you have easy access to all side vents and panels We suggest that you closely consider the required location for your ice bath prior to filling your bath Please account for the attachment point to drain the surplus water We also ...

Page 12: ...ur MiPod machine to the wrong voltage or this will cause serious damage not covered under warranty MiPod Chill Hot Dual Temp Componentscomplywith Compact Series4 MadeinAustralia IC22000 On Off 3 1 2 5 6 4 Electronic Panel Box 1 Main Power Switch 7 6 Override Button 5 Ethernet Port for DATAcable 3 Serial Number Label 2 Main Power Socket 4 Safety Test Button 220V 7 Voltage 5 ...

Page 13: ...n the back of your screen Please note a power cable is not required for the screen The screen will receive its power from the blue DATA cable supplied Mount the screen on a wall or anywhere you want using the wall mount bracket kit included Please note the DATA cable supplied is 5m long 3 Turn on SWITCH Turn the Main Power Switch ON and check that the screen turns on correctly If that is the case ...

Page 14: ...re fitted as it must be custom made once on site Your compact will come with PVC barrel unions suited for 1 inch PVC pipes PVC pipes MiPod water outlets are not included Installation is recommended to be completed by a certified plumber Insulation of the pipes is a must for the full length of the two water pipes otherwise a lot of cold energy will be lost Remote Screen Optional With MiPod Remote v...

Page 15: ...Davey Cartridge Filter additional water outlets are manufactured on the shell of your MiPod when ordered at the same time This must be ordered in advance and cannot be retro fitted The connecting PVC pipes between the filter and the MiPod are not included Installation is recommended to be completed by a certified plumber Insulation of the pipes is a must for the full length of the two water pipes ...

Page 16: ...with a hose A permanent water connection is not required Simply fill with a hose over the Mipod to at least cover the internal top water outlet If this is not followed the machine will draw air and cause the safety system to shut the system down To empty water from MiPod simply connect a 12mm hose to the drain valve and OPEN valve to let water go Drain Valve Make sure the drain valve is in the CLO...

Page 17: ...17 Recommended water level ...

Page 18: ...Get Started O3 ...

Page 19: ......

Page 20: ...perating Screen will appear 3 Initial Connection Your touch screen will usually connect to the MiPod main operating page automatically however in some circumstances this page may appear because it has not yet recognized your MiPod If this happens after a short time a small blue square appears at the top left of the screen as shown below Simply tap anywhere on this small blue square to connect manu...

Page 21: ... of continuous 24 7 operation If you wish to have your pool available at your desired temperature at any time of the day or night then you can leave it running continuously at very low operating cost The MiPod is so efficient that if you use it every day it will cost less to operate if you leave it running continuously A sophisticated power management system is included that will automatically use...

Page 22: ...t by clicking on the Menu Button and selecting SETTINGS Temperature Unit You can switch between Centigrade or Fahrenheit Light Dark mode You can change the display mode of your screen from Light to Dark mode Volume You can change the volume of the system sounds by clicking repeatedly or Energy Saving You can set different levels of energy saving Level 1 provides full cooling power Level 5 saves th...

Page 23: ...ime and do the same to set a Change Over Time in between sessions then click SAVE LOCK You can also lock your screen by entering a 4 digit passcode This will limit the access to the settings of the chiller To set a passcode go to MENU LOCK Set a PIN and enter a combination of 4 numbers You can remove this settings by selecting Remove PIN INFO All information about your machine is available in Menu...

Page 24: ...SafetyProcedures O4 ...

Page 25: ... button is located on the Main Power Switch ELECTRIC SHOCK PROTECTION LIMITATIONS All iCool machines have built in electrical safety residual earth leakage protection systems It can only protect against devices actually connected to the iCool including the water pump It can not protect against faults in other unrelated electric devices in the area All electric devices in any pool area must only be...

Page 26: ... pump especially designed for the purpose The pumps we provide are resistant to chlorine and salt water at normal concentrations but the use of chemicals should be kept within the range normally recommended for swimming pools to prolong the life of the pump and the titanium heat exchanger tanks inside the cooling unit Never use bromide as it is highly corrosive to all materials and can cause irrit...

Page 27: ... to freeze in the MiPod or its machinery If extreme cold conditions are expected empty the water from the unit If not being used do not allow the internal tank to freeze solid Either empty the water or add salt or anti freeze to lower the temperature at which the water freezes If not in use drain the unit and store at ambient temperature Operation in Very Hot Weather iCool machines are very powerf...

Page 28: ...TechnicalSupport O5 ...

Page 29: ......

Page 30: ...ion is lack of water flow It can occur if air is trapped in the water pipes or in the pump or if flow is restricted by some sort of blockage it could be hair dust or any other debris The machine will attempt to clear it automatically several times by surging the pump to dislodge air If after several attempts it cannot correct the lack of water flow it will shut the machine down and warn you that a...

Page 31: ... the temperature below about 7ºC or 45ºF it is occasionally possible in certain climatic conditions for the heat exchange tanks to freeze solid This will block most or all the flow of water It should be understood that in order to cool the pool water to these extremely low temperatures the system must cool to at least 5ºC below the set temperature to allow for losses and this takes it very close t...

Page 32: ...ected temperature If your MiPod is not cooling or heating at all but seems to be running correctly it may most likely be out of refrigeration gas and needs to be re gassed Re gassing can be done by your local refrigeration technician Once re gassed you must absolutely provide enough ventilation to keep the machine within a safe operating temperature System Too Hot Warning Your MiPod can move large...

Page 33: ...it OFF and ON again and waiting for 30 seconds The connection should be automatic Software Not Loading If the software doesn t load for any reason we recommend turning the unit OFF and ON first to see if that solves the issue If the issue persists please contact iCool Support Condensation Please note that your unit is a very powerful chiller and condensation will occur inside of it Water may be vi...

Page 34: ...product fault is covered by our Standard One Year Warranty please check the Product Warranty Statement available on our website iCoolsport may offer assistance via email to fix your issue recommend a local repair service or ask for the unit to be shipped back for repair Any repair does not extend the warranty period Local Repair All local repairs must be approved in writing by iCool and if your un...

Page 35: ...est your package will be the more expensive it will be to ship amake sure to pack it as small as possible International returns your freight company may ask for the value of the item to send it to Australia To avoid having to pay duties again on your product we recommend setting it to a maximum of 100 and making sure to note that it is being returned for REPAIR only and that will be re exported fo...

Page 36: ......

Reviews: