Temperature Settings
When your iCool starts up, you are offered 3
different ways to choose a water temperature
setting. Whichever method you choose it eventually
takes you to the main run screen. If you make no
setting, the system will automatically insert 15°C.
(around 59ºF) In this case you can proceed directly
to start the pump and cooling system.
If you want to make a different temperature setting,
you touch the CHANGE setting button and this will
take you to the water temperature setting screen
illustrated below, where you can use the up and
down arrows to select the temperature you require.
After you make your setting touch the start button to go to the main
screen where you can start both the pump and the cooling system and
where all relevant temperature information is clearly displayed.
After you start the system running you can view the actual water
temperature in full screen by touching the blue POOL TEMPERATURE
square at the bottom left of the main screen for more than 2 seconds
When your iCool starts up, the first screen you
will see offers you a system settings button. THE
BEST SETTINGS ARE AUTOMATICALLY SELECTED
so there is usually no need to use this feature. The
three settings you can change are the fan speed
range, the temperature from degrees Centigrade to
Fahrenheit and the sound level from the screen.
Main Cooling Fan Speed
This allows you to set the main cooling fan to either NORMAL or QUIET
MODE. Generally you should always leave it in the NORMAL mode
which is fully automatic and allows the system to control the fan speed
to give the very best efficiency and fastest cooling.
Quiet Mode
Models with 3 speed fans only
If you are in a very quiet environment you can select QUIET MODE, but
you must be aware that this will reduce the cooling ability of the system,
however it will be quieter overall as the fan will not run higher than 60%
of maximum unless there is a risk of overheating, in which case the
safety system will turn the fan back to high no matter what the setting.
The NORMAL setting is used to give absolute maximum cooling power
where higher fan noise is not a problem. On a normal day this gives about
30% more cooling than in the QUIET MODE. If cooling seems lower than
normal, check to see if this feature was previously set to Quiet Mode.
Temperature Display Scale
This can be set to either Centigrade or Fahrenheit and this changes all
of the displays throughout the entire system. When you first start the
iCool it will normally start in Centigrade as this is the world standard.
Due to complex decimal calculations between Cº and Fº there may be
minor difference in the true Fº displays. This has no effect on actual
cooling accuracy.
The sound level adjusts the sounds made by touching the screen and
by the alarms. Normally it should be left on high to assist with settings
and to make sure alarms are heard.
A red dot indicates which setting
is selected in each of the available settings.
10
iCool Compact
FUNCTIONS OF THE TOUCH BUTTONS
SYSTEM SETTINGS
SYSTEM SETTINGS
MAIN SCREEN
MAKE NEW SETTINGS
Touch Buttons Screen
Water Temperature Setting Screen
Water Temperature Full Screen
27
°
10
°
14
°
10
°
27
°