iCool Compact Series Owner'S Manual Download Page 7

08

iCool Compact

STEP 6

Now that you have pre set your desired temperature and started the 

circulating pump, notice that the pump button will have changed from 

start to stop. You can use this same button to start and stop the pump at  
any time.

Now, touch the start system button and the cooling cycle will begin. The 

water will be cooled to your preset temperature and the system will then 
cycle to maintain it at that temperature automatically. The SYSTEM can 
only be started once within any 3 minute period to avoid overloading 
the compressor. So if you don’t hear it start do not touch the START 

SYSTEM  again  ,  it  will  start  automatically  after  the  3  minutes  safety 

period elapses.

In an emergency you can stop all functions immediately by touching 
the “ALL STOP

” button  However, if the cabinet is hot, only the fan may 

continue to run until the cabinet has cooled.

For  the  safety  of  users,  you  can  not  set  temperatures  below  5°C  or 

above 45°C. (40°F-112°F)

Some models have the ability to heat as well as cool

If your iCool is a contrast MODEL, then depending on the temperature 

you set, it will either heat or cool the water automatically to reach your 

preset temperature and then maintain it at that temperature. It heats by 
modern heat pump technology using as much as 70% less electricity 
than conventional electric spa heaters.

Setting up to use the Heating Mode

For safety reasons you can only initiate the heating mode at the time 

the unit is first switched on. You can not change to heating while you 

are using it in the cooling mode or vice versa. You must switch off at the 
main switch and start again to change modes.

Your iCool selects either cooling or heating automatically

If you set the temperature to a value that is BELOW the current water 

temperature in your pool it will automatically begin COOLING when you 

touch the START SYSTEM button. 

If you set the temperature to a value that is ABOVE the current water 

temperature in your pool it will automatically begin HEATING when you 

touch the START SYSTEM button. 

To use the heating function use the up down arrows to select the hot 
temperature you require up to 45ºC (or 108ºF) and then touch the 
START button. This takes you back to the main operating screen where 
you can now start the PUMP and the SYSTEM as usual. The status bar 
on top of the unit will turn RED when you touch the START button to 
indicate that your iCool is now heating. It will continue to heat until it 
reaches your pre set temperature and then hold that temperature for 
as long as you wish.

You must use a pool cover when heating the water

We all understand that heat rises, so you must use a cover on top of 

your pool when heating it or you will lose a large amount of the heat 
energy into the room and it will take much longer to heat the water.

The Loss of Water Flow Warning Screen

If water stops flowing for more than two minutes the iCool will sound 
a warning and shut down. This screen shown here will appear.

The Water Flow Warning Screen also provides an option to over ride 
the water flow protection system in the rare situation of a false alarm.

Once you use this function to disarm the flow safety monitor nothing 
will stop the system even if water is not flowing and this can seriously 
damage the pump as it will have no lubrication or cooling from the 
water. 

This over ride function is only to be used for short periods where it is 
essential to keep your system operating until the reason for the false 
alarm can be determined and corrected.

Water flow can also stop if the heat exchanger tank is frozen solid

If you set the temperature below about 7ºC or (45ºF) it is occasionally 
possible in certain climatic conditions for the heat exchanger tank to 
freeze solid which will block the flow of water. 

In order to cool the pool water to these extremely low temperatures the 
system must cool to at least 5 to 7ºC below the set temperature and 
this takes it very close to the temperature that water freezes solid. 

Following international safety standards your iCool will not accept 
water temperature settings below 5ºC or (40ºF) as this would put 
athletes using the system unattended at risk of hypothermia. The iCool 
is easily powerful enough to freeze the water and if this happens the 
safety screen above will appear and the system will stop. 

WARNING

Never use the water flow protection overide option unless you 
are absolutely certain that the system has stopped because of 
a false water flow alarm

Warning Screen

Summary of Contents for Compact Series

Page 1: ...Owners Manual iCool COMPACT...

Page 2: ...t offers more chilling power than the Cool model plus it has a larger touch screen and a multi speed cooling fan A perfect fit for those on a tight budget needing a step up in power and more features...

Page 3: ...cterial solution especially formulated use with for ice bath pools and equipment Please see our website for details 04 iCool Compact Occasionally you may experience some difficulty getting the water t...

Page 4: ...ce as the pool It must not be above the pool STEP 1 2 QUICK START GUIDE The following is a quick start guide to get your iCool up and running quickly however you should read the entire manual to get t...

Page 5: ...tem Status Bars will flash white The STATUS BARS on each side at the front of the iCool will change colour or flash to give a clear indication of each function While the software is loading the status...

Page 6: ...that the systems check was successful and that your iCool is ready to use The Status bars glow BLUE when only the pump is running GREEN when the cooling system is running and RED when the heating syst...

Page 7: ...108 F and then touch the START button This takes you back to the main operating screen where you can now start the PUMP and the SYSTEM as usual The status bar on top of the unit will turn RED when you...

Page 8: ...rapy however for safety reasons you cannot change directly from heating to cooling or cooling to heating To do this you must switch off the entire system at the main switch and start again This is req...

Page 9: ...e NORMAL mode which is fully automatic and allows the system to control the fan speed to give the very best efficiency and fastest cooling Quiet Mode Models with 3 speed fans only If you are in a very...

Page 10: ...e using is the contrast model which also provides heating for contrast therapy you cannot set the temperature above 45 C 112 F because of the risk of scalding These temperature limits have been set af...

Page 11: ...downside is that untrained people sometimes like to play with the colourful touchscreens As with any sophisticated piece of equipment when people start pressing buttons at random anything can happen...

Page 12: ...kwards from page to page using the buttons on the right hand side of the help screens or you can return to be main help menu page at any time The built in illustrated help system is a revolutionary ne...

Page 13: ...eat are involved Fortunately we have very few such problems but as an added benefit we have built into all iCool s a complete manual override system that allows your iCool to operate effectively even...

Page 14: ...w Noise 1500 Cubic Ft per Minute 3 Speed 1200 Cubic Ft per Minute 3 Speed 1200 Cubic Ft per Minute 3 Speed 1200 Cubic Ft per Minute Power Plug 3 Pin Heavy Duty to suit country 3 Pin Heavy Duty to suit...

Page 15: ...All iCool Machines are Designed Manufactured in Australia Published 2016 by iCool Australia Pty Ltd iCool is a Registered Trade Mark worldwide Contact info icoolsport com www icoolsport com...

Reviews: