12
iCool Lite
Temperature Limitations
Because of the dangers of hypothermia in the case of an unattended
athlete using the pool, your system will not allow you to set
temperatures below 5°C/40°F. If the model you are using is the contrast
model which also provides heating for contrast therapy you cannot set
the temperature above 45°C/112°F because of the risk of scalding.
These temperature limits have been set after wide consultation with
the sporting industry around the world.
There are no demonstrated benefits in using water temperature lower
than 5°C or above 45°C and therefore the risk of doing so is not justified.
Timing Functions
Your iCool offers a number of very useful timing
functions including a real-time clock, a countdown
timer to time recovery and training sessions and a
timer to shut down the system automatically at a
predetermined time after use. To set up and use
these functions touch the timer function button
on the home screen. You can reach this screen by
using the back 1 button or the home button.
In order to use the auto shut down function you first
need to set the time of day on the built-in clock.
To set the clock touch the set main clock button on
the timing functions screen and the time setting display on the bottom
right of the screen will begin flashing. You must set it while one of the
numbers is flashing by using the up down and left right keys. Once you
stop using these keys for more than a few seconds the display will
stop flashing and the time showing is set into the system and the clock
begins operating.
The iCool clock operates in the universal 24-hour time style.
Automatic System Shutdown Timer
You can preset your iCool to shut down at any time
up to five hours in the future. This is very convenient
for coaches and specialists who may want to leave
the training area early but want to make sure that
the system is not left running needlessly. To set
this time, touch the set shut down button and the
clock digits on the bottom right of the screen will begin to flash as
with setting the clock. Use the same up down and left right arrows to
set the number of hours and minutes you wish to elapse before the
system automatically shuts down. The system automatically begins
Time Setting Screen
11:25
TIMER FUNCTIONS
SET MAIN CLOCK
the countdown and will stop when the time you set reaches zero. The
time remaining before shutdown is displayed on the main clock display
screen.
As the same arrows are used to set all three time functions, to avoid
confusion, a red dot appears next to be button of the function being set.
Recovery Session Timer Functions
A very popular and useful feature of your iCool is the session countdown
timer.
This allows you to accurately control the immersion times of athletes
and to repeat those times as often as needed. This is an essential
part of successful cryo recovery therapy and is just as important as
maintaining accurate and consistent temperatures, which of course
your iCool does perfectly.
The session timer is set up from the main time setting screen by
touching the set countdown button. The numbers on the setting screen
in the bottom right-hand corner will begin to flash and you can use
the left, right and up, down arrows to change the time in minutes and
seconds. Once you have set the time you want your athletes to remain
in the bath, touching the display countdown full-screen button will take
you to the screen illustrated on the next page. This screen allows you
to see the countdown from a distance and also to control it in various
convenient ways. The current pool temperature and the outside
temperature will also be displayed.
The count down can be set for once only, or it can repeat automatically
as many times as you like. This is particularly convenient if you have a
number of athletes using the same pool at the same time. The system
beeps for each of the last five seconds at the end of each countdown
to warn the athletes to get ready to get either in or out of the pool
and pauses for several seconds to allow the changeover before the
countdown begins again (if it is set in the repeat mode).
SET SHUT DOWN
DISPLAY
COUNTDOWN
FULL
SCREEN
SET COUNT DOWN
DISPLAY COUNTDOWN
DOWN
UP
RIGHT
LEFT
Summary of Contents for COMPACT Cool
Page 1: ...Owners Manual iCool Lite ...
Page 2: ......