iControl Remote Installation Manual
ICRIM-EN-
April 20
20
5
Section Title
5
5
55
Definitions
There are two different types of iControl Remote controllers, depending on the pivot panel type. Before
installing iControl Remote, it is important to identify the main panel installed in the center of the pivot and
ensure that the controller selected is compatible with it.
• PIVOT PANEL: BASIC AUTOREVERSE.
Controllers compatible: All BAR (Basic AutoReverse) models
Reference numbers: 90017-WL8B, 90017-WL9B, 90017-3G-B, 90017-4G-B.
The controller is prewired and programmed to change direction using a neutral pulse on the yellow/red wire.
• PIVOT PANEL: STANDARD AUTOREVERSE.
Controllers compatible: Controllers compatible: All SAR (Standard AutoReverse) models
90017-WL8BS 90017-WL9S, 90017-3G-S, 90017-4G-S.
The controller is prewired and programmed to change direction using a 110V pulse on the direction
wires (brown for forward and orange for reverse).
If an ICR2 is installed on an old system or one from another manufacturer, make sure the controller is com-
patible with the main pivot panel as stated in the following instructions:
For all iControl Remote Basic Autoreverse:
• Check whether the machine starts with a 110V pulse (3 seconds) on the return safety wire (yellow wire).
• Check whether the machine stops and remains stopped 5 seconds after opening the return safety
circuit (disconnecting the yellow wire for 5 sec.).
• Check whether the machine changes direction with a neutral pulse on the autoreverse wire (yellow/red).
• Check that the neutral and earth wires are connected together inside the main panel.
For all iControl Remote Standard Autoreverse:
• Check whether the machine starts with a 110V pulse (3 seconds) on the direction wires (brown wire
for forward and orange wire for reverse).
• Check whether the machine changes direction with a 110V pulse (3 seconds) on the direction wires
(brown wire for forward and orange wire for reverse).
• Check whether the machine stops and remains stopped 5 seconds after opening the return safety
circuit (disconnecting the yellow wire for 5 sec.).
• Check that the neutral and earth wires are connected together inside the main panel.
Note: The main panel of the pivot must be equipped with the autoreverse relays and it must be configured
in autoreverse mode to be able to change direction.
Note: In machines from other manufacturers, the colour scheme might be different. It might also be neces-
sary to install additional electronic components for the controller to be able to execute the start, stop and
change direction functions properly.
After checking this functionality, you can install the iControl Remote.
Should they not work properly,
contact our technical service for assistance.