background image

ICRIM-EN-

April 20

20

3

Section Title

3

3

33

Components

iControl Remote Installation Manual

iControl Remote is a solution that monitors and controls the operation of the center pivot and which consists 

of the following components:

The iControl Remote v2 controller family bundles together different types of communications within a com-

mon electronic device. This manual is applicable to all iControl Remote v2 controllers.

The different existing models are summarized in the following table:

Components

Location

Operation

ICR2

PIVOT

(last tower)

Electronic device that monitors and controls individual 

Center Pivot. It is installed inside the last tower box.

ICONTROL 

CLOUD

CLOUD

Cloud application which displays the pivot status on a web 

interface and enables it to be acted upon.

GATEWAY

FIELD

(near the center 

pivots)

This is only necessary for the ICR2-Wireless controller.

Electronic device acting as gateway between the different 

controllers (ICR2-W) lying within its range and the server 

iCONTROL REMOTE CLOUD.

Family

Communications

Pivot panel type

Model

Reference

Number

iControl 

Remote 

2 (ICR2)

Wireless 868 MHz

 Basic AutoReverse

ICR2-W868BAR

90017-WL8B

 Standard AutoReverse

ICR2-W868SAR

90017-WL8S

Wireless 900 MHz

 Basic AutoReverse

ICR2-W900BAR

90017-WL9B

 Standard AutoReverse

ICR2-W900SAR

90017-WL9S

3G

Basic AutoReverse

ICR2-3GBAR

90017-3G-B

Standard AutoReverse

ICR2-3GSAR

90017-3G-S

4G

 Basic AutoReverse

ICR2-4GBAR

90017-4G-B

Standard AutoReverse

ICR2-4GSAR

90017-4G-S

Gateway

Wireless 868 MHz

AC Power Supply

ICRGWAY8

Solar Power Supply

ICRGWAY8S

Wireless 900 MHz

AC Power Supply

ICRGWAY9

Solar Power Supply

ICRGWAY9S

ICR2 CONTROLLER (all versions)

GATEWAY

(only for ICR2-Wireless versions)

Summary of Contents for 90017-3G-B

Page 1: ...iControl Remote Installation Manual V2 ICRIM EN April 2020 ...

Page 2: ...il 2020 2 2 Contents iControl Remote Installation Manual HOW TO INSTALL ICONTROL REMOTE V2 TOWER BOX Components 3 Definitions 5 Installation connections and commissioning 6 Troubleshooting 8 Electric Schematics 10 ...

Page 3: ...nd enables it to be acted upon GATEWAY FIELD near the center pivots This is only necessary for the ICR2 Wireless controller Electronic device acting as gateway between the different controllers ICR2 W lying within its range and the server iCONTROL REMOTE CLOUD Family Communications Pivot panel type Model Reference Number iControl Remote 2 ICR2 Wireless 868 MHz Basic AutoReverse ICR2 W868BAR 90017 ...

Page 4: ...Installation Manual ICRIM EN April 2020 4 Components iCONTROL REMOTE CLOUD SERVICE iCONTROL REMOTE TOWER BOX iControl Remote Last Tower Box Pressure sensor with 1 4 connection Pressure control sensor sensor 3 4 adapter ...

Page 5: ...ellow wire Check whether the machine stops and remains stopped 5 seconds after opening the return safety circuit disconnecting the yellow wire for 5 sec Check whether the machine changes direction with a neutral pulse on the autoreverse wire yellow red Check that the neutral and earth wires are connected together inside the main panel For all iControl Remote Standard Autoreverse Check whether the ...

Page 6: ... step 7 the pink line will be connected to Terminal T3 instead of Terminal T24 in the main panel For iControl Remote to be able to control the End Gun Solenoid this must be con nected to Terminal 11 in the Last Tower Box Connect the light in the last tower to A1 at the motor contactor 3 Install the water pressure sensor kit and connect it to the M12 connector of iControl Remote Note The sensor mus...

Page 7: ...ord is 393945 Note This login is provisional for the installer and it will be canceled once the controller is assigned to its owner in the administration platform iCAP It is very important that once the installation is com plete the equipment should be assigned to its owner in iCAP 10 An interface similar to that shown on previous pages will appear which includes a widget for the iCon trol Remote ...

Page 8: ...te with the cloud service To check this you must open the cover of the tower box it is not necessary to open the controller lid and you will see a green LED at the bottom of the controller close to the cable outlet Steady The radio is not linked to any node Flashing 0 5s The radio is linked to a node Can the Gateway communicate with the server Review the Gateway installation manual 3G 4G MODELS 90...

Page 9: ...e v2 POWER supply status LED GREEN supply present OFF no supply Reset button Communications status LED ICR2 Wireless Steady The radio is not linked to any node Flashing 0 5s The radio is linked to a node ICR2 3G 4G Steady There is no connection with the server Flashing 0 5s There is a connection with the server ...

Page 10: ...v2 to End Tower Connections STANDARD AUTOREVERSE wiring Note These diagrams are applicable to the Standard Autoreverse panel of Western and Pierce BASIC AUTOREVERSE 90017 WL8B 90017 WL9B 90017 3G B 90017 4G B Wiring of iControl Remote v2 to a Basic AR panel Changes to be made in the Basic AR panel to be able to feed the iControl Remote v2 iControl Remote v2 to End Tower Connections BASIC AUTOREVER...

Page 11: ...iControl Remote Installation Manual ICRIM EN April 2020 11 11 11 11 11 Electric Schematics Wiring iControlRemote to Standard AR panel bis ...

Page 12: ...iControl Remote Installation Manual ICRIM EN April 2020 12 Electric Schematics iControlRemote V2 StandardAR Wiring ...

Page 13: ...iControl Remote Installation Manual ICRIM EN April 2020 13 13 13 13 13 Electric Schematics Wiring iControlRemote to Basic AR Panel bis ...

Page 14: ...iControl Remote Installation Manual ICRIM EN April 2020 14 Electric Schematics iControlRemote V2 BasicAR Wiring ...

Page 15: ...15 ...

Page 16: ...16 ICRIM EN April 2020 www icontrolremote com ...

Reviews: