background image

         12 
 

 

 

11. Priming the system 

 

  
The 

iCON

 

NXT Pro 

is supplied with two 1” BSPT male swivel unions.  

 
The controller can be removed from the pump by removing the stainless steel retaining clip. 
Once the clip is removed the connection fitting will slide from the controller body. 
 

 

 

Due to the non-return mechanism inside the controller, the pump should be primed 

before fitting the controller OR filled through the pump priming port. 

 

12. Standards and Approvals

 

 

SAA Approvals

 is accredited by the Joint Accreditation 

Service of Australia and New Zealand (JAS-ANZ) as a third 
party certification body to issue of Certificates of Approval for 
declared and non-declared electrical equipment that has 
proven to comply with the safety requirements of the 
applicable Australian Standard. 

 

Pumps that carry the AS/

NZ4020 Drinking Water Approval

 

demonstrate compliance with requirements of Australia & 
New Zealand Standards of products that come into contact 
with water intended for human consumption. This approval 
also ensures that the water coming from the pump will not be 
contaminated by toxic materials or metals. It also means the 
water will not support the growth of micro-organisms and will 
not cause a change in taste or appearance. 

 

CE marking

 is a certification mark that indicates conformity 

with health, safety and environment. The CE marketing 
represents a manufacturer’s declaration that products comply 
with the EU’s New Approach Directives. These directives not 
only apply to products within the EU but also for products that 
are manufactured in or designed to be sold in the EEA. 

 

 

Summary of Contents for NXT Pro

Page 1: ...1 Auto Restart Pump Controller iCON NXT Pro User Manual 808035 BIA NXTPRO...

Page 2: ...when the upper setting is achieved Both the start and stop pressure can be selected by the user A Pressure Tank is required if operating in Mode 2 The iCON NXT Pro offers a number of other protection...

Page 3: ...l specifications 5 6 Warnings 6 6 1 Cautions 7 7 Electrical Connections 8 8 Display 9 9 Programming 10 10 Installation 11 11 Priming the system 12 12 Standards and Approvals 12 13 Operation 13 14 nXt...

Page 4: ...s manual Warning Electrical safety Warning Potential consequences of use outside of intended application s Includes environmental condition warnings Mandatory warning Warning to disconnect power Read...

Page 5: ...ccumulator removed Pump Start pressure Default 2 2 bar User adjustable 0 5 6 0 bar Pump stop Flow less than 0 9 lpm in Mode 1 User adjustable 1 8 9 0 bar in Mode 2 Maximum pressure 10 bar Pressure dif...

Page 6: ...ers to protect the power supply The fitment of additional surge protection is recommended Never open the cover while controller is connected to electrical supply This appliance is not intended for use...

Page 7: ...NXT Pro controller It should not be dismantled 6 1 5 No regular maintenance of the NXT Pro controller is required 6 1 6 Fitment and replacement must be carried out by competent skilled and qualified...

Page 8: ...lead and AS NZ 3112 Type 1 3 pin male power plug for connecting to mains power The Plug and Play version of the iCON NXT Pro is fitted with a 10 amp rated IEC C13 appliance connector When the iCON NXT...

Page 9: ...PROGRAMMING PX X Start and Stop Pressure CX X Current F1 Mode 1 pressure controller Default cut in 2 2 bar F2 Mode 2 pressure switch Default cut in 2 2 bar Default cut out 9 bar OL Overload protection...

Page 10: ...gramming Important Note The controller allows for a maximum of 10 seconds between button presses when programming If no button press is detected after 10 seconds the controller will exit the adjustmen...

Page 11: ...head pressure of water above the controller is less that the starting cut in pressure otherwise the pump will not start See table below The controller is to be installed on the discharge of the pump p...

Page 12: ...en to comply with the safety requirements of the applicable Australian Standard Pumps that carry the AS NZ4020 Drinking Water Approval demonstrate compliance with requirements of Australia New Zealand...

Page 13: ...ar Set to Mode 1 the iCon NXT Pro controller will stop the pump for 4 reasons Once flow has stopped due to a tap being closed In the event that the pump has run out of water If the control is subject...

Page 14: ...xceeded Pushing the RESET button rotates the display indication System Pressure Current Draw Operational Status Underload Dry Run condition assumes the Pipe Flow parameter PF is enabled The following...

Page 15: ...id that a pressure vessel is essential Most systems suffer from small water losses dripping taps leaking cisterns feeding low demand items such as ice makers or Reverse Osmosis filtration units the ad...

Page 16: ...0 Cth for goods purchased in Australia and the Consumer Guarantees Act 1993 NZ for goods purchased in New Zealand 4 Our goods come with guarantees that cannot be excluded under the Australian Consumer...

Page 17: ...g operation 4 Internal electronics may be damaged Pump Failure 1 Water failure 2 Suction problems Pump failure is not necessarily the fault of the controller RED LED LACK OF WATER Flashing 1 Pump not...

Page 18: ...18 17 Notes...

Page 19: ...19 18 Notes...

Page 20: ...changes in product specifications 2020 Copyright White International Pty Ltd TM WARNING Please be aware that various brands products depicted within this document are subject to trademark patent or de...

Reviews: