24
MAINTENANCE
Regular maintenance is important for optimal
performance and to reduce wear. Inspect and properly
tighten all parts each time the elliptical is used.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap.
IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not turn on, make sure that the
power cord is fully plugged in.
If lines appear in the console display, see HOW TO
CHANGE CONSOLE SETTINGS on page 22 and
adjust the contrast level of the display.
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the dis-
played heart rate appears to be too high or too low, see
step 5 on page 17.
HOW TO CALIBRATE THE INCLINE SYSTEM
If the incline frame is not functioning properly, it may
need to be calibrated. To calibrate the incline frame,
press and hold the Calorie button for several seconds
until the test mode appears in the display.
Next, press the Calorie button again. Then, press the
Incline increase or decrease button to calibrate the
incline frame. The incline frame will move upward and
downward as it calibrates.
When the incline frame stops moving, it is calibrated.
Then, press the Calorie button repeatedly to exit the
calibration mode.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted. To adjust the reed
switch, first
press the power switch to the off posi-
tion and unplug the power cord.
Next, remove the
four M4 x 16mm
Screws (not
shown) from the
Large Storage
Foot (27), and
then remove the
Large Storage
Foot. Then,
remove the two
M4 x 16mm
Screws (not shown) from the Top Shield (37), and
then use a standard screwdriver to pry the Top Shield
upward off the elliptical.
Then, look into the access opening and locate the
Reed Switch (58). Rotate the Pulley (66) until a
Magnet (41) is aligned with the Reed Switch.
Slightly loosen the two indicated M4 x 16mm Screws
(61), slide the Reed Switch (58) slightly toward or
away from the Magnet (41), and then retighten the
Screws.
Plug in the power cord, press the power switch to the
reset position, and rotate the pulley for a moment.
Repeat these actions until the console displays correct
feedback.
When the reed switch is correctly adjusted, press the
power switch to the off position, unplug the power cord
and reattach the top shield and the large storage foot.
Then, plug in the power cord.
MAINTENANCE AND TROUBLESHOOTING
37
27
66
58
41
61
Summary of Contents for NTEL99413.1
Page 5: ...5...