background image

iCON 

iSOLAR 3”

 PDP Instruction Manual

   

 

 

 

3.   Introduction

 

 

Welcome to the iCON iSOLAR revolution!  

The 3” helical rotor 

iSOLAR PDP3 

range provides a ‘plug and play’ 

kitset solution that 

requires  only  moderate  DIY  skills  to  install  and  has  little  ongoing  maintenance 

requirements. 

The  iSOLAR  PDP3  can  be  installed  down  a bore,  in  a tank or  fitted  to  a  pontoon  to 

supply from an open body of water. 

No more external energy costs! Just harvest the sun to move your water. 

While this kit is very simple, please read this manual fully and carefully before you start. 

Progressive Cavity / Helical Rotor pumps can produce extremely high pressures and 

any electrical energy must always be treated with care. Stay safe and get the important 

details right so you can enjoy the benefits of your purchase. 

 

4.   Key Features and Protections 

 

 

 

  Low voltage permanent magnet DC motor 

  High efficiency MPPT and Vector Control 

  Dry run protection from low level float 

  Easy-to-install output side control from  

 

a float or pressure switch 

 
 
 

Glossary of Electrical Terms 

Term 

Definition 

Voc (V)

 

Volts open circuit, nothing connected

 

Vmp or Vmpp (V)

 

Volts maximum power point, under load 

Isc (A)

 

Amps short circuit

 

Imp or Impp (A) 

Amps maximum power point 

DC Power in Watts 

Vmp x Impp 

 
 
 

  Over-load protection 

  Over-current protection 

  Over-voltage protection 

  Low-voltage protection 

  Lost Phase protection 

  Stall protection 

 

Summary of Contents for iSolar 808691

Page 1: ...l Solar Pump Complete Solution Kit 808691 BIA PDP3 SOLAR250 808692 BIA PDP3 SOLAR370 808694 BIA PDP3 SOLAR750 Brushless submersible helical motor iCON PDP3 Solar Controller 30 meters cable Non return...

Page 2: ...Electrical Connections 6 7 8 Display 8 9 Display Functions Explained 8 10 Alarm Parameters and Meaning 9 11 Installation 10 13 12 Operation summary 14 13 Warranties Terms and Conditions 15 2 ISO 7010...

Page 3: ...r pumps can produce extremely high pressures and any electrical energy must always be treated with care Stay safe and get the important details right so you can enjoy the benefits of your purchase 4 K...

Page 4: ...for the internal electronics to discharge before opening the cover The controller is IP65 rated but should not be exposed to direct sunlight Install the controller where it has excellent ventilation a...

Page 5: ...tructions The Max Voc and Max Current A capabilities of the motor and the controller must always be respected Fitting additional or incorrectly rated panels will cause serious harm or irreparable harm...

Page 6: ...the controller before removing the cover to access the low voltage circuit connections The controller is IP65 rated It should not be exposed to direct sunlight Install the controller where it has exce...

Page 7: ...p to x Meters Watts Panels Max VOC Vmpp Amps 10 25 30 50 75 100 CROSS SECTION MM2 300 1 x 300 48V 35 10 2 5 2 5 2 5 6 10 10 600 2 x 300 96V 70 10 2 5 2 5 2 5 2 5 4 6 900 3 x 300 150V 105 10 2 5 2 5 2...

Page 8: ...ration Press again to turn the pump controller off To see if the pump is running press SWITCH to display RPM SWITCH Display Scroll Repeated presses scroll through real time operating values Voltage Pu...

Page 9: ...causes P0 Hardware over current Motor and Controller mismatched Motor short circuit or cable damage P43 Phase protection Motor phase absence or U V W wiring issue P46 Stall protection Motor and Contr...

Page 10: ...10 iCON iSOLAR 3 PDP Instruction Manual 11 Installation...

Page 11: ...perature has an impact on pump performance Recommended water temperature of 10 to 40 C A check valve is included with the kit It must be installed on the pump outlet or at the well head Additional che...

Page 12: ...to assist your decision regarding the best angle for your situation As a rule of thumb solar panels should be more vertical during winter to gain most of the low winter sun and flatter during summer...

Page 13: ...example The pressure loss values per 100m of pipe length are for 16 bar rated pressure supply pipe at 25lpm Pipe size Friction loss per 100m of pipe at 25 lpm If unsure increasing the pipe size by on...

Page 14: ...on cloudy days The display values will be constantly changing as the pump adjusts to optimise the output based on the available input power Note that the wattage value indicates what the pump is curre...

Page 15: ...nd Consumer Act 2010 Cth for goods purchased in Australia and the Consumer Guarantees Act 1993 NZ for goods purchased in New Zealand 4 Our goods come with guarantees that cannot be excluded under the...

Page 16: ...or changes in product specifications 2020 Copyright White International Pty Ltd TM WARNING Please be aware that various brands products depicted within this document are subject to trademark patent or...

Reviews: