Operating instructions 

 

Setting working parameters 

o

 

Press the Function button (7). The screen will display ‘dE1’ and Flash. ‘dE1’ 

means the pump is working at its max head. In this mode, only the starting 

pressure can be adjusted and the pump will stop working at its max head. 

‘dE2’ means the controller is in mode 2. In this mode, the cut in and cut 

out pressure can be set as desired. The mode can be changed between 1 

and 2 by pressing the up and down arrow. 

 

Setting the pressure 

o

 

In mode ‘dE1’, press func, the screen will display ‘dE1’ and flash, press func 

again, the screen will display L00, this means the cut in pressure can be 

adjusted using the up and down arrows. The adjustment range is 0.5-6 bar  

o

 

In mode ‘dE2’, press func, the screen will display ‘dE2’ and flash, press func 

again, the screen will display L00, this means the cut in pressure can be 

adjusted using the up and down arrows; press func again, the screen will 

again display L00, this means that the cut out pressure can now be 

adjusted using the up and down arrow. The adjustment range is 0.8-9.8bar 

 

When making adjustments to the pressure settings, the controller will exit its 

adjustment state if no buttons have been pushed for 3 seconds. 

 

Pressure settings will be kept in the controller memory if a power failure should 

occur. 

 

Once working parameters have been set, they can be checked by pressing the up 

and down arrows. In mode dE1, only the cut in pressure can be checked, in mode 

dE2 press the up arrow to check the cut out pressure and the down arrow to check 

the cut in pressure. 

 

When the screen displays ‘P—‘ or ‘A—‘ and flashes, the pump will attempt restart 

in 30min 

 

If no water is supplied to the system, i.e no water in tank or closed supply/suction 

pipe, the system will run the following sequence: switch off after 20 seconds if no 

water detected, stop for 10 seconds, run for 40 seconds stop for 10 seconds, run 

for 40 seconds. If no water is detected after this initial sequence, the status light 

will flash orange, indicating that it is now in a dry-running protection status. When 

the status light is flashing, it means the pump will restart after 24 hours in the 

sequence mentioned above. The system will repeat this every 24 hours until water 

is detected. 

 

The pump can be restarted at any time by pressing the reset button. 

 

 

 

 

 

 

 

 

 

Summary of Contents for BIA-iPRESS

Page 1: ...BIA iPRESS DIGITAL PUMP CONTROLLER AUTO RESTART USER MANUAL Please read carefully before using ...

Page 2: ...f a button o Overload protection o Over pressure protection o Built in protection to prevent the motor from starting and stopping too often o Anti seize function if pump has not operated for some time o Auto restart function when supply tank re fills 3 Installation Installation and maintenance of the controller must be performed by a qualified professional This controller has been designed to work...

Page 3: ...240V 240V 240V 415V 415V ...

Page 4: ...3 Control Functions Start pressure can be set Start Stop pressure can be set Start pressure Stop pressure ...

Page 5: ...s 0 8 9 8bar When making adjustments to the pressure settings the controller will exit its adjustment state if no buttons have been pushed for 3 seconds Pressure settings will be kept in the controller memory if a power failure should occur Once working parameters have been set they can be checked by pressing the up and down arrows In mode dE1 only the cut in pressure can be checked in mode dE2 pr...

Page 6: ... light flashing 1 The controller is damaged 2 Damaged suction pipe 1 Water shortage 2 Pump is broken 3 Leakage of pump inlet 4 Pump head lower than start pressure 0 3 bar mode 1 5 Pump head is lower than stop pressure mode 2 Display P 1 The controller is damaged 2 The pressure sensor is damaged The actual pressure in the pipe line is more than 9 9 Bar for longer than 5 seconds Display A 1 The contr...

Page 7: ...the event of a failure The controller itself has no spare parts supplied to the purchaser and must be maintained by a suitably qualified professional The distributor Manufacturer are not responsible for any damage caused by any direct or indirect influence to the controller All details in this manual are subject to change without prior notice ...

Page 8: ...stralia and New Zealand if a defect in the product appears during the warranty period If you believe that you have purchased a defective product and wish to make a claim under this warranty contact us on our Sales Hotline on 1300 783 601 or send your claim to our postal address or fax line below and we will advise you as to how next to proceed You will be required to supply a copy of your proof of...

Page 9: ...w that cannot be excluded including those in the Competition and Consumer Act 2010 Cth is expressly limited to a in the case of products the replacement of the product or the supply of equivalent product the payment of the cost of replacing the product or of acquiring an equivalent product or the repair of the product or payment of the cost of having the product repaired is at the discretion of Wh...

Reviews: