Icon Process Controls truflo TK Series Manual Download Page 2

TABLE OF CONTENTS

1. Product Description
2. Parts TK Series
3. Product Selection
4. Specifications
5. Procedure to Rotate Display
6. Programming Models TKP | TKM
        6.1  Programming NPN Pulse Output Models TKP | TKM Only
        6.2  Programming NPN Pulse Control Function Models TKP | TKM Only
        6.3  Mode of NPN Pulse Output TKP | TKM Models
        6.4  K-Factors for TK
        6.5  Programming TKS Model Only
        6.6  Programming TKS Model Only Program Relay Set Point and Relay Delay (Prevents Relay Chatter)
        6.7  Relay ON - OFF Options For TKS Series Only
        6.8  General Terms
7. Standard Pipe Size
8. Pressure vs. Temperature (psi, water, non-shock)
9. Wiring Diagram
        9.1  TKP - Flow Rate + Flow Tot NPN Pulse Diagram
        9.2  TKM - (4-20mA or 0-5V DC + NPN Pulse) Flow Rate + Flow Tot Pulse Diagram
        9.3  TKS NPN (Flow Rate + Relay + Pulse) Diagram
10. Installation Positions

11. Warranty, Returns and Limitations

02
03
03
03
04
04
05
05
06
06
06
07
07
07
08
08
08
08
08
09
09

11

Installation Positions

10

© Icon Process Controls Ltd. All Rights Reserved

02

for more information visit www.iconprocon.com

Multi

-

Function Paddle Wheel Flow Meter

TKS

|

 TKP 

|

 TKM 

ROTATOR

 SERIES MANUAL

Summary of Contents for truflo TK Series

Page 1: ...rves the right to implement changes without prior notice Programming Multi Function Paddle Wheel Flow Meter TKS TKP TKM ROTATOR SERIES MANUAL Icon Process Controls Ltd All Rights Reserved for more inf...

Page 2: ...lay Chatter 6 7 Relay ON OFF Options For TKS Series Only 6 8 General Terms 7 Standard Pipe Size 8 Pressure vs Temperature psi water non shock 9 Wiring Diagram 9 1 TKP Flow Rate Flow Totalizer NPN Puls...

Page 3: ...tistokes 2 Parts TK Series 3 Product Selection 1 2 3 4 5 6 7 EXAMPLE TKP 25 P E T RS M 1 SERIES e s l u P y a l e R h t i w r e t e M w o l F l e e h W e l d d a P S K T a b TKP Paddle Wheel Flow Mete...

Page 4: ...amming Lock Out Feature TKP TKM Series Lck 10 Unlocked Factory Default IF Lck is Changed from the 10 the Flow Meter will be in Lockout Mode LCK 10 Default To Unlock ensure Lck is set to 10 Programming...

Page 5: ...tep 5 TKP TKM Series Only CV Display Reads 0 SV Display Reads 0 0 Totalizer Default 0 0 Flow Rate Default CV Current Value SV Programmed Value 1000 Default One Pulse Per Gallon Default Flow Rate Pulse...

Page 6: ...rogrammed K Value Preset Do Not Change F SET Flow Meter TKS Alarm GPM Programming Units of Flow Press Step 4 Program Flow Units 0 1 2 Ut 0 LPM Ut 1 GPM Default Ut 2 Kiloliter KL F SET Flow Meter TKS A...

Page 7: ...6 7 Relay ON OFF Options For TKS Series Only ALt 1 ALt 0 ALt 3 ALt 2 CV Current Display Value Flow Rate d GPM Hysteresis Measured around Relay Set Point Measured in Gallons SV Selected Value Programm...

Page 8: ...White 0V Totalizer Pulse Output NPN RS 485 1 OPT RS485 is a Special Order Item Flow Rate Pulse Output NPN Brown Yellow Grey Black 10 30 VDC 4 20mA or 0 5V Blue White 0V Totalizer Pulse Output NPN Tot...

Page 9: ...NO COM Load 1 4 Grey 5 6 3 1 AMP TKP Yellow Grey wires with RS 485 Option Only Current output 4 20mA 120 max Voltage output 0 5V 10K min TKM Series 0 5VDC Optional 4 20mA is Standard Icon Process Cont...

Page 10: ...er Bag Filter or Y Strainer Filtering Device upstream to Avoid the Paddle Wheel from being damaged by the solids or fibers max 10 Particle Size Not to Exceed 5mm Cross Section or Length Please do not...

Page 11: ...cal or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repai...

Reviews: