Engineers Notes 

 

These  notes  are  only  intended  for  use  by  an 
engineer  qualified  to work  with high  voltage  triodes 
like the 845/805. Owners should refer any problems 
to a dealer or service agent.  
The  amplifier  may  be  inverted  by  supporting  the 
transformers  on  non  abrasive  surface  (e.g.  dense 
foam,  books  etc)  which  allows  space  between  the 
805s and the work surface. 
 

Safety 

Before  removing  base  disconnect  the  power  cord. 
Allow 20 minutes for the HT to discharge.  
 

Amplifier dead. 

Check  the  20mm  mains  fuse  in  the  IEC  socket  at 
rear  of  the  amplifier,  if  dead  there  is  a  spare 
included. Or the fuse in the plug (if applicable). 
Amplifier lit but not working. 
There  is  a  250ma  HT  fuse  located  on  the  chassis, 
with spares  attached  to  the  base.  If  the  fuse  blows 
again  a  VARIAC  or  variable  transformer  will  be 
useful to operate the amplifier on reduced power in 
order the trace the fault or overload. 
Make sure the bias for the 805s is correct. If the AC 
fuse  is  blowing  with  the  HT  fuse  disconnected 
suspect the bridge rectifier or power supply. 
 

230v to 120v Conversion. 

Take  the  precautions  as  above.  It  is  necessary  to 
change  the  primary  power  windings  from  series  to 
parallel.  Remove  either  AC  lead  from  the  bridge 
rectifier and join it to the other terminal. 

The “centre” 

tap  are  the  two  leads  that  will  be  found  joined 
together.  Replace  with  these  two  and  solder  to  the 
first terminal. A larger value AC fuse will be needed 
in the IEC socket. 

120v to 230v Conversion. 

This is changing the two primary windings to series. 
Remove either pair of AC leads from an AC input to 
the  bridge  rectifier.  Join  together  and  insulate.  The 
other  pair  of  AC  leads  should  be  separated  and 
soldered  to  each  AC  input  of  the  bridge  rectifier.  A 
lower  value  AC  fuse  will  be  needed  in  the  IEC 
socket. 
 

Summary of Contents for MB 805 SE

Page 1: ...ve 805 has to do all the work of both the up and down parts of the waveform In order to go down the valve must be running at 100 of its maximum power unlike push pull amplifiers where the idle current...

Page 2: ...mplifier finish Internal wiring check Check Triode mode N A Run min 6 hour test Check input Output Valve Bias level v Sound Quality Channel Balance Valve Microphony Valve Seating Hum level L R mv RF T...

Page 3: ...t rear Page 3 MB805 Layout and Features If you are inserting the MB 805 valve for the first time it may be helpful to observe the slot in the valve base to indicate the degree of rotation needed to fi...

Page 4: ...tral terminal and Green Yellow to Earth terminal 6 SWITCH ON The blue mains indicator should light up The 805s will glow bright yellow You will likely hear a humming noise for a few seconds this is no...

Page 5: ...and play some music with plenty of bass e g dance music preferably in mono FM tuners are usually switchable to mono and stand the speakers close together If correct you should hear plenty of bass if...

Page 6: ...valve This could be due a faulty 805 or one of the 805 internal fuses blowing A symptom of this would be no bias voltage at the test point Also the valve would not be as hot as normal Refer to an engi...

Page 7: ...s ground by unscrewing the 0 speaker terminal and tightening the probe in the exposed hole And the red probe in the test socket adjacent to the valve on test Set the Icon meter to 2000mv or the black...

Page 8: ...the mains plug at least 20 minutes beforehand This will enable dangerous voltages to dissipate and the valves to cool down If possible check the bias setting before you attempt to change the valve s i...

Page 9: ...e It is not guaranteed for commercial Public Address use or use in other situations The guarantee becomes void if the unit has been modified in any way not approved by Icon Audio Please contact us 10...

Page 10: ...or variable transformer will be useful to operate the amplifier on reduced power in order the trace the fault or overload Make sure the bias for the 805s is correct If the AC fuse is blowing with the...

Reviews: