11 TECHNICAL FEATURES
Dimension:
113.5 mm x 75.0 mm x 25.5 mm (excluding antenna and RS-232 connectors)
Weight:
120 g
Operating temperature
-30°C to +85°C
Environmental protection
IP 40
Casing
Plastic
Input power options
8-30 V DC (typical 12 V DC)
Current peak
1.2 A (@ 8 V)
Typical average power
consumption for an upload
period of 1 hour
40 mA @ 12 V
Note: Average power consumption varies in function of the configuration and the
network
WAN
3G:
•
Five bands UMTS (WCDMA/FDD ; 800, 850, 900, 1900 and 2100 MHz)
4G:
•
Seven bands UMTS/HSPA+ (WCDMA/FDD; 800, 850, 900, 1700/2100, 1800, 1900
and 2100 MHz)
•
Twelve bands LTE (700, 800, 8520, 900, 1700, 2100, 1800, 1900, 2100, 2600 MHz)
3G and 4G:
•
Region: Global
•
EDGE/GPRS Class 12
•
Quad-band GSM (850, 900, 1800 and 1900 MHz)
12 WARRANTY
Icoms Detections warrants its hardware products to be free from defects in workmanship and materials, under normal use
and service, for a period of two (2) years from the date of despatch from Icoms Detections premises, except for the batteries
for which a warranty period of six (6) months applies.
If a product does not operate as warranted during the applicable warranty period, Icoms Detections shall, at its option,
either repair the defective unit, either deliver to the buyer an equivalent product or part to replace the defective item. All
products that are replaced become property of Icoms Detections.
The defective product must be returned to Icoms Detections within the applicable warranty period. The defective product
must be shipped back to Icoms Detections pre-paid, insured and wrapped in the original or similar shipping package to
ensure that it will not be damaged during transportation, and must be accompanied by appropriate paperwork (ask first for a
R
eturn
M
aterial
A
uthorisation number) detailing the nature of the defect experienced.
Icoms shall be under no liability in respect of any defect arising from normal wear and tear, wilful damage, negligence,
damage due to inappropriate packaging, abnormal working conditions, failure to follow Icoms Detections instructions
(whether oral or in writing), misuse, improper installation, alteration or repair without Icoms Detections approval.
13 FURTHER INFORMATION
13.1
L
EGAL NOTIFICATION
The Gemalto 3G modem is in compliance with following requirements:
•
RED Directive 2014/53/EU.
•
RoHS 2 2011/65/EC
•
WEEE 2003/108/EC
•
FCC ID: QIPEHS6
•
IC: 7830A-EHS6
The Gemalto 4G modem is in compliance with following requirements: