5
OTHER FUNCTIONS
5-7
Using the Emergency Call function (Continued)
Operation
Time
Enters the
Emergency mode.
Sends an
Emergency call.
[PTT]
[PTT]
[PTT]
No operation
is detected.
ON Timer
Reminder Timer
Emergency Timer
[KEY]
If pushing any key
during Reminder
Timer, the Emergency
mode is canceled.
Acceleration
Time
Enters the
Emergency mode.
Sends an
Emergency call.
Stationary
Sensitivity
ON Timer
Reminder Timer
Emergency Timer
Operation
[KEY]
[PTT]
If pushing any key
during the Reminder
Timer, the Emergency
mode is canceled.
No operation
is detected.
No motion is
detected.
If moving during the Reminder
Timer, the Emergency mode
is canceled.
The transceiver enters the Emergency mode through
the following functions, depending on a presetting:
D
The Lone Worker function
When no operation occurs for the ON Timer preset time�
L
If a user pushes any key before the Reminder
Timer set time expires, the Emergency mode is
canceled�
Lone Worker With Stationary:
•When no operation occurs for the ON Timer preset
time�
AND
• The transceiver is detected as stationary (no motion)
for the ON Timer set time�
L
If a user pushes any key, or moves the transceiver
before the Reminder Timer set time expires, the
Emergency mode is canceled�
Example:
•ON Timer:
60 minutes
•Reminder Timer: 60 seconds
NOTE:
The Lone Worker function may not properly work, depending on the surrounding environment such as
obstructions, weather condition, and so on�
Icom is not responsible for the destruction or damage caused by using the Lone Worker function�