4
REPEATER AND DUPLEX OPERATION
4-4
The “Auto repeater” item in the Initial Set mode
Auto Repeater function is OFF.
Auto Repeater function is ON
(For only duplex).
Auto Repeater function is ON
(For duplex and tone encoder).
Auto Repeater function (For only the USA version)
The USA version automatically activates the repeater
settings (DUP– or DUP+ and tone encoder ON/OFF),
when the operating frequency falls within the general
repeater output frequency range. It deactivates them
when outside of the range.
1. Hold down [ ] for 1 second to turn OFF the
power.
2. While holding down [
Y
] and [
Z
], turn ON the
power to enter the Initial Set mode.
3. Push [
Y
] or [
Z
] to select the Auto Repeater item
(RPt).
4. Rotate [VOL] to set the Auto Repeater function to
“R1,” “R2” or “OF.”
• “RPt.OF”: The Auto Repeater function is OFF.
• “RPt.R1”: The Auto Repeater function is ON
(For only duplex).
• “RPt.R2”: The Auto Repeater function is ON
(For duplex and tone encoder).
5. Push [# ENT] to exit the Initial Set mode.
Frequency range and offset direction
Frequency range
Duplex direction
145.200–145.495 MHz
146.610–146.995 MHz
“–” is displayed.
147.000–147.395 MHz
“+” is displayed.