5-4
ADJUSTMENT
ADJUSTMENT ITEM DISPLAY
CONDITION
OPERATION
HF-flat
16 HF BPF0 flat
• Set the test equipment to:
Frequency: 0.2515
MHz
Modulation: None
Level: +40
dB
μ
†
(–67 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound 1
second later.)
17 HF BPF1 flat
• Set the test equipment to:
Frequency: 1.1015
MHz
18 HF BPF2 flat
• Set the test equipment to:
Frequency: 1.8215
MHz
19 HF BPF3 flat
• Set the test equipment to:
Frequency: 2.6015
MHz
20 HF BPF4 flat
• Set the test equipment to:
Frequency: 3.6015
MHz
21 HF BPF5 flat
• Set the test equipment to:
Frequency: 5.1015
MHz
22 HF BPF6 flat
• Set the test equipment to:
Frequency: 7.0815
MHz
23 HF BPF7 flat
• Set the test equipment to:
Frequency: 10.1015
MHz
24 HF BPF9 flat
• Set the test equipment to:
Frequency: 18.1515
MHz
25 HF BPF10 flat
• Set the test equipment to:
Frequency: 28.1015
MHz
26 HF BPF11 flat (L)
Set the test equipment to:
Frequency: 0.5015
MHz
27 HF BPF11 flat ( M)
• Set the test equipment to:
Frequency: 14.1515
MHz
28 HF BPF11 flat (H)
• Set the test equipment to:
Frequency: 29.9015
MHz
HF-flat
(Preamp ON)
29 HF PRE flat (L)
• Set the test equipment to:
Frequency: 0.5015
MHz
30 HF PRE flat ( M)
• Set the test equipment to:
Frequency: 14.1515
MHz
31 HF PRE flat (H)
• Set the test equipment to:
Frequency: 29.9015
MHz
HF-flat
(ATT)
32 HF ATT 10dB flat
• Set the test equipment to:
Frequency: 14.1515
MHz
Modulation: None
Level: +40
dB
μ
†
(–67 dBm)
33 HF ATT 20dB flat
• After the adjustment, the receiver shows the HF receive adjustment menu.
• Push [EXIT] to return to the main menu screen.
5-3
HF RECEIVE ADJUSTMENT (CONTINUED)
†