5 - 2
ADJUSTMENT
RECEIVER’S
CONDITION
OPERATION
ADJUSTMENT
ITEM
VALUE
REFERENCE
FREQUENCY
1 • Frequency: 439.800 MHz
• Connect a frequency counter to "2nd
LO" line on the RF UNIT as illustrated
below.
247.050 MHz
(±120 Hz)
5-2 FREQUENCY ADJUSTMENT
1) Select an adjustment item using
[BAND]
/
[TS]
.
2) Set or modify the adjustment value as specifi ed using
[DIAL]
, then push
[V/M]
to store the adjustment value..
RF UNIT
¤
LOCATION
The 2nd LO line