5 - 1
¤
QUITTING ADJUSTMENT MODE
Turn the receiver’s power OFF.
¤
ENTERING ADJUSTMENT MODE
1)
Connect the JIG cable (see the illust below) to the [SP] jack.
2)
Push and hold
[FUNC]
,
[BAND]
,and
[
Y
]
, turn the receiver’s power ON.
¤
KEY ASSIGNMENTS FOR THE ADJUSTMENT MODE
EQUIPMENT
GRADE AND RANGE
EQUIPMENT
GRADE AND RANGE
JIG cable
Modifi ed 3-conductor 3.5 (d) mm plug
(See the illust below)
Standard signal
generator (SSG)
Frequency range : 100 kHz to 1.2 GHz
Output level
: –20 to +107 dBµ
(–127 to 0 dBm)
Frequency counter
Frequency range
: 0.1–300 MHz
Frequency accuracy : ±0.1 ppm or better
Input level
: Less than 1 mW
¤
REQUIRED EQUIPMENTS
5-1 PREPARATION
JIG cable
To [SP]
3-conductor 3.5 (d) mm plug
(CLONE)
To [SP]
(GND)
Adjust the value for the item
Selects next adjustment item
(without storing the value)
Selects previous adjustment item
• Stores adjustment value
• Starts automatic adjustment
Adjustment item
Adjustment frequency
SECTION 5. ADJUSTMENT
PROCEDURE
• JIG CABLE