![Icom IC-R10 Instruction Manual Download Page 80](http://html2.mh-extra.com/html/icom/ic-r10/ic-r10_instruction-manual_3555878080.webp)
13
TROUBLESHOOTING
75
If your receiver seems to be malfunctioning, please check the
following points before sending it to a service center.
PROBLEM
POSSIBLE CAUSE
SOLUTION
REF.
No power comes on.
• The installed batteries are exhausted.
(A slight current flows in the circuits even when
the power is OFF.)
• The batteries have been installed in reverse po-
larity.
• Charge the batteries or place new dry cell batter-
ies in the battery case.
(Remove the batteries if you will not be using the
receiver for a long time.)
• Re-install the batteries in the correct orientation.
p. 8
p. 8
No audio is output.
• [VOL] is turned to the minimum position.
• Earphone or headphone is connected.
• The [SQL] is turned too far clockwise.
• VSC function is activated.
• Turn [VOL] to a suitable level.
• Disconnect the earphone or headphone.
• Turn the [SQL] counterclockwise.
• Release the VSC function.
p. 10
p. 11
p. 38
Weak reception, excessive
distortion or too much
noise.
• Not centered on the frequency.
• Wrong receive mode is selected.
• ATT function is activated.
• The [SQL] (RF gain) is set too far clockwise (when
USB, LSB or CW is selected).
• Batteries are nearly exhausted.
• Set to the center frequency using a small tuning
step.
• Select the correct receive mode.
• Release the ATT function.
• Turn the [SQL] (RF gain) counterclockwise.
• Charge the batteries or place new dry cell batter-
ies in the battery case.
p. 13
p. 12
p. 65
p. 11
p. 8
Cannot tune frequency via
the keypad or [DIAL]
• Lock function is ON.
• While pushing [FUNC], push [
(EDIT)
LOCK] to turn
the lock function OFF.
p. 64
Cannot charge the installed
Ni-Cd batteries.
• [CHARGE] is set to the OFF position.
• Set [CHARGE] to the ON position.
p. 8