5 - 1
SECTION 5
ADJUSTMENT PROCEDURE
EQUIPMENT
GRADE AND RANGE
EQUIPMENT
GRADE AND RANGE
RF power meter
(terminated type)
Measuring range : 0.1–10 W
Frequency range : 100–300 MHz
Impedance : 50
Ω
SWR : Less than 1.2 : 1
Standard signal
generator (SSG)
Frequency range : 0.1–300 MHz
Output level : 0.1
µ
V to 32 mV
(–127 to –17 dBm)
Frequency counter
Frequency range : 0.1–300 MHz
Frequency accuracy : ±1 ppm or better
Sensitivity : 100 mV or better
FM deviation meter
Frequency range : 30–300 MHz
Measuring range : 0 to ±10 kHz
Audio generator
Frequency range : 300–3000 Hz
Output level : 1–500 mV
Impedance : 600
Ω
External speaker
Input impedance : 8
Ω
Capacity : More than 1 W
Attenuator
Power attenuation : 30 dB
Capacity : More than 10 W
5-1 PREPARATION
REQUIRED TEST EQUIPMENTS
When adjusting IC-M34, the optional CS-M34 ADJ
ADJUSTMENT SOFTWARE
(Rev. 1.0 or later), OPC-478 (RS-232C type) or OPC-
478U/UC (USB type)
CLONING CABLE
and a JIG cable (modified OPC-1668, see page 5-2) are required.
Microsoft and Windows are registered trademarks of
Microsoft Corporation in the U.S.A. and other countries.
STARTING SOFTWARE ADJUSTMENT
(1) Connect IC-M34 and a PC with OPC-478/UC, OPC-1668 and JIG CABLE.
(2) Turn the transceiver ON.
(3) Boot up Windows
®
, and click the program group 'CS-M34 ADJ’ in the ‘Programs’ folder of the [Start] menu,
then CS-M34 ADJ’s window appears.
(4) Click ‘Adjust’ on the CS-M34’s window, then IC-M34’s up-to-date condition appears.
(5) Set or modify adjustment value as specified.
▄
SYSTEM REQUIREMENTS
(for
CS-M34 ADJ
ADJUSTMENT SOFTWARE
)
• Microsoft
®
Windows
®
98/98SE/Me/2000/XP
• RS-232C serial port (D-sub 9 pin) or USB port
▄
ADJUSTMENT SOFTWARE INSTALLATION
q
Quit all applications when Windows is running.
w
Insert the CD into the appropriate CD drive.
e
Doublelick the “Setup.exe” contained in the ‘CS-M34 ADJ’ folder in the CD drive.
r
The “Welcome to the InstallShield Wizard for CS-M34 ADJ” will appear. Click [Next>].
t
The “Choose Destination Location” will appear. Then click [Next>]
to install the software to the destination folder. (e.g. C:\Program Files\Icom\CS-M34 ADJ)
y
After the installation is completed, the “InstallShield Wizard Complete” will appear. Then click [Finish].
u
Eject the CD.
i
Program group ‘CS-M34 ADJ’ appears in the ‘Programs’ folder of the start menu,
and ‘CS-M34 ADJ’ icon appears on the desk top screen.