19
7
SET MODE
New2001
D
LCD contrast selection
“LC”
The contrast of the LCD can be turned ON (high contrast) and
OFF (low contrast).
D
Power save function
“PS”
The power save function reduces current drain by deactivat-
ing the receiver circuit for preset intervals.
• ON : The power save function is turned ON. The power save func-
tion will activate when no signal is received, and no operation
is performed for 5 sec.
• OFF: The power save function is turned OFF.
D
Self check function
“SC”
The self check function checks transceiver conditions by it-
self, and informs you in case a problem is found. The follow-
ing items are checked after the power is turned ON, then it
switches to operation mode.
• Temperature : Outside of –25°C to +65°C (approx.)
• Connected battery voltage
• Water intrusion
When error messages as shown below are displayed, see
troubleshooting for advice. (p. 27)
Temperature error
Battery voltage error
Water intrusion error
Push
Self check OFF (default)
Self check ON
Push
Power save ON
(default)
Power save OFF
Push
LCD contrast ON
(default)
LCD contrast OFF
IC-M31.qxd 03.10.20 9:18 AM Page 19 (1,1)