6-3
ADJUSTMENT
TRANSCEIVER’S
CONDITION
OPERATION
ADJUSTMENT
ITEM
VALUE
TX OUTPUT
POWER
(High)
1
• CH.:
16
• Transmitting
• Connect an RF power meter to the
antenna connector.
[RF Power (High)]
4.5 W
(L_High)*
2
[RF Power (L_High)]
2.5 W
(Low)
3
[RF Power (Low)]
0.75 W
(E_Low)*
4
[RF Power (E_Low)]
0.45 W
*For only
[FRG]
version.
6-4 TRANSMIT ADJUSTMENTS
1) Select an adjustment item using [
↑
]/[
↓
] on the PC's keyboard.
2) Set or modify the adjustment value as specified using [
←
]/[
→
] on the PC's keyboard, and then push [ENTER].
ADJUSTMENT
TRANSCEIVER’S
CONDITION
OPERATION
ADJUSTMENT
ITEM
VALUE
RX SENSITIVITY
1
NOTE:
When "RX SENSITIVITY" is re-adjusted, "SQUELCH" must be re-adjusted too.
• CH.:
16
• Receiving
• Connect an SSG to the antenna connector and
set it as;
Frequency: 156.800 MHz
Level
†
:
+30 dBµ (–77 dBm)
Modulation: 1 kHz
Deviation: ±3.0 kHz
[BPF]
Push [ENTER]
on
[BPF]
.
(Automatic
adjustment)
SQUELCH
1
NOTE:
When "RX SENSITIVITY" must be adjusted before "SQUELCH." And when "RX SENSITIVITY" is
re-adjusted, "SQUELCH" must be re-adjusted too.
• CH.:
16
• Receiving
• Connect an SSG to the antenna connector and
set it as;
Frequency: 156.800 MHz
Level
†
:
–4 dBµ
(–111 dBm)
Modulation: 1 kHz
Deviation: ±3.0 kHz
[Noise]
Push [ENTER]
on
[Noise]
.
(Automatic
adjustment)
†
The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.
6-3 RECEIVE ADJUSTMENTS
1) Select an adjustment item using [
↑
]/[
↓
] on the PC's keyboard.
2) Set or modify the adjustment value as specified using [
←
]/[
→
] on the PC's keyboard, and then push [ENTER].