Adjustment for IC-F3061T/S,IC-F3161T/S,IC-F3161DT/DS
Adjustment
No.
Value
REF No.
CK.POINT
Adjustment Condition & Tuning
NOTICE FOR RX
For verify of RX adjustment must be done with
ADJUSTMENTS
a SG set as;
Freq.=1kHz
Dev.=70%
Connect an 8 ohms load to the SP terminal.
RX SENSITIVITY
ADJUSTMENT
Set the SG as;
FREQUENCY
LEVEL
(ADJ screen)
BPF C ALL
RSSI line
maximum sensitivity.
RX SENSITIVITY
Verify the sensitivity as below.
VERIFY
Sensitivity
ANT connector
EXT. SP
S-METER
"RX SENSITIVITY" must be adjusted before
ADJUSTMENT
"S-METER"."S-METER" must be adjusted
if "RX SENSITIVITY" is adjusted again.
Setting S3 level
Set the SG as;
(ADJ screen)
Freq.
RSSI
Level
RSSI S3 Level
ANT connector
Setting S1 level
Set the SG as;
(ADJ screen)
Freq.
RSSI
Level
RSSI S1 Level
ANT connector
around 136MHz
+20dBu
around 136MHz
+23dBu
around 136MHz
Adjust the "BPF C ALL" on the ADJ screen for
Less than -10 dBu (@12dB SINAD)
-7dBu
PAGE5