background image

 

 

ADJUSTMENT 

Adjustment           No.     Adjustment Condition & Tuning                        Value    Ref. No.   CK. Point 

Checking AF Output            Set the signal generator output level to  

                               +60 dBu. The transceiver and SG connection 

                                                              is the same as the squelch adjustment above. 

                               Adjust the transceiver volume until the  

                                                              distortion meter reads 5%. 

                               Check that the AF output value at this point 

                                                              as below. 

                                                                                                                                                                                Over 

    AF Output                        More than 0.35W                                    0.35W   

                                                                                                                                                                              @ 8 ohm 

                                                                                                                                                                                load 

 

Checking RX S/N               Set the signal generator output level to 

                                                              +60 dBu. Adjust the AF volume so that the 

                                                              AF output is 50% of the rated value.   

                               Check that the RX S/N in the bandwidth is 

                                                              as the values below. 

                                                   

                                                                  WIDE                            More than 40 dB                                    Over 40dB 

                                                                  NARROW                    More than 34 dB                                    Over 34dB 

                                                     

Checking  Howling             Set the signal generator output to +60 dBu 

                               as in RX adjustment, and for non-modulation. 

                               Next, set the internal speaker for operation, 

                                                              and turn the AF volume up to maximum to 

                               check that howling does not occur. 

 

Checking Maximum            While still in the AF output check status, 

RX Current                                        rotate the volume control clockwise to obtain 

                               the maximum AF output. Check that the  

current consumption at this time is as the 

value below. 

               

                                 Max. RX Current          Less than 300 mA           Less than             PWR Con 

                                                                                        300mA 

 

 

 

Summary of Contents for IC-F11

Page 1: ...s follows by means of spreadable coil L16 Adj Freq Highest Band Freq TX Side 4 0V 4 0V L16 Lock Voltage Set the transceiver to the lowest Check band frequency and check that each of the LV voltage is...

Page 2: ...tions below Hi Power 4 0 6 0W 4 0 6 0W ANT Con L2 Power 1 2 2 8W 1 2 2 8W L1 Power 0 5 2 0W 0 5 2 0W Current Check at Check that the in band power consumption TX is within the specifications below 4 0...

Page 3: ...output terminal Connect a millivolt meter or a 600 ohm out put impedance CR oscillator to the trans ceiver s mic terminal Deviation Set the CR oscillator to a 1 kHz sine wave Adjustment 150mVrms and i...

Page 4: ...e attenuator DTCS 5 TONE to the antenna terminal then reset so that DTMF DEVIATION each signaling type can be output DTCS CODE 007 CTCSS 88 5 Hz 5 TONE CCIR 11111 DTMF Auto Dial Setting Set the linear...

Page 5: ...hat the TX S N in the bandwidth is as the values below WIDE More than 40 dB Over 40dB ANT Con NARROW More than 34 dB Over 34dB Adjusting RX When there is no particular set limits set Sensitivity the R...

Page 6: ...band center frequency Set the signal generator to the settings below Modulation Freq 1kHz WIDE 3 5 kHz NARROW 1 75 kHz SG Output Level 14 dBu In this condition using the adjustment software raise the...

Page 7: ...volume so that the AF output is 50 of the rated value Check that the RX S N in the bandwidth is as the values below WIDE More than 40 dB Over 40dB NARROW More than 34 dB Over 34dB Checking Howling Se...

Page 8: ...ondition Tuning Value Ref No CK Point Checking Standby Without connecting anything to the ACC Power Consumption socket check that the standby power con sumption is as the value below Standby Current L...

Reviews: