background image

Cmd. Sub cmd.

Data

Description

00

See p. 13

Send the frequency data (transceive)

01

See p. 13

Send the mode data (transceive)

02

*

1

See p. 13

Read the band edge frequencies

03

*

1

See p. 13

Read the operating frequency

04

*

1

See p. 13

Read the operating mode

05

*

2

See p. 13

Set the operating frequency

06

*

2

See p. 13

Set the operating mode

07

Select the VFO mode

00

Select VFO A

( In the satellite mode, selects the VFO 

mode.)

01

Select VFO B

(In the satellite mode, “FA” (NG) is returned.)

A0

Equalize VFO A and VFO B

B0

Exchange MAIN and SUB Bands

D0

Select the main band

D1

Select the sub band

D2*

00

Send/read main band selection

01

Send/read sub band selection

08

*

2

Select the Memory mode

0001 to 0099 Select the Memory channel (Including the 

satellite mode)

(0001=M-CH01, 0099=M-CH99)

0100 to 0105 Select program scan edge channel  

1A/1B to 3A/3B

( 0100/0101 (1A ch/1B ch),  

0104/0105 (3A ch/3B ch))

0106, 0107 Select call channel C1/C2

(0106 (C1 ch), 0107 (C2 ch))

09

Memory write

0A

Memory copy to VFO

0B

Memory clear

  0C

*

1

See p. 13

Read frequency offset

  0D

*2

See p. 13

Send frequency offset

0E

00

Cancel the scan 

01

Start a Programmed/memory scan 

02

Start a Programmed scan 

03

Start a 

F scan 

12

Start a Fine programmed scan 

13

Start a Fine 

F scan

22

Start a Memory scan

23

Start a Select memory scan

24

Start a Mode Select scan

Ax

*

2

(x=1 to 7)

Select 

F scan span

( x=1 (±5 kHz), x=2 (±10 kHz),

 x=3 (±20 kHz), x=4 (±50 kHz),

 x=5 (±100 kHz), x=6 (±500 kHz),

 x=7 (±1 MHz))

B0

*

2

Clear the Select channel setting

B1

*

2

Set as select channel

( The previously set number by CI-V is set 

after turning power ON, or “1” is selected if 

no selection is performed.)

01 to 03

Set the channel as a Select channel

(01=SEL1, 02=SEL2, 03=SEL3)

B2

*

2

00 to 03

Set the Select memory scan channel

(00=ALL, 01=SEL1, 02=SEL2, 03=SEL3)

D0

*

2

Set Scan resume OFF

D3

*

2

Set Scan resume ON (Close&Delay)

0F

*1

00

Read Split OFF setting

01

Read Split ON setting

11

Read DUP– operation

12

Read DUP+ operation

13

Read DD Repeater Simplex mode (RPS)

00

*

2

Set Split function OFF

01

*

2

Set Split function ON

Cmd. Sub cmd.

Data

Description

0F

10

*

2

Set the simplex operation

11

*

2

Set DUP– operation

12

*

2

Set DUP+ operation

13

*

2

Set DD Repeater Simplex mode (RPS)

10*

00 to 11

Send/read the tuning step

( 00=OFF (10 Hz or 1 Hz),

 01=100 Hz, 02=500 Hz, 03=1 kHz, 

 04=5 kHz, 05=6.25 kHz, 06=10 kHz, 

 07=12.5 kHz, 08=20 kHz, 09=25 kHz,

 10=50 kHz, 11=100 kHz)

11*

00

Send/read attenuator OFF setting

10

Send/read 10 dB attenuator setting

13

00

Speech all data with voice synthesizer

(S meter level, frequency and mode)

01

Speech the operating frequency and S meter 

level by voice synthesizer

02

Speech the operating mode by voice synthesizer

L

 The mode is announced after the ongoing 

speech.

14* 01

0000 ~ 0255 Send/read the AF level 

(0000=Minimum to 0255=Maximum)

02

0000 ~ 0255 Send/read the RF gain level

(0000=Minimum to 0255=Maximum)

03

0000 ~ 0255 Send/read the squelch level

(0000=Minimum to 0255=Maximum)

06

0000 ~ 0255 Send/read the NR level

(0000=0%, 0255=100%)

07

0000 ~ 0255 Send/read [TWIN PBT] (PBT1) position

( 0000=max. Counter Clockwise, 0128=center, 

0255=max. Clockwise)

08

0000 ~ 0255 Send/read [TWIN PBT] (PBT2) position

( 0000=max. Counter Clockwise, 0128=center, 

0255=max. Clockwise)

09

0000 ~ 0255 Send/read CW pitch (5 Hz steps)

( 0000=300 Hz, 0128=600 Hz, 0255=900 Hz)

0A

0000 ~ 0255 Send/read RF power 

( 0000=Minimum to 0255=Maximum)

0B

0000 ~ 0255 Send/read MIC gain

(0000=Minimum to 0255=Maximum)

0C

0000 ~ 0255 Send/read keying speed

(0000=6 WPM to 0255=48 WPM)

0D

0000 ~ 0255

Send/read Notch filter setting

( 0000=max. Counter Clockwise, 0128=center, 

0255=max. Clockwise)

0E

0000 ~ 0255 Send/read the COMP level

(0000=0 to 0255=10)

0F

0000 ~ 0255 Send/read the Break-IN Delay setting

(0000=2.0 d to 0255=13.0 d)

12

0000 ~ 0255 Send/read NB level

(0000=0% to 0255=100%)

15

0000 ~ 0255 Send/read Monitor audio [MONI] level

(0000=0% to 0255=100%)

16

0000 ~ 0255 Send/read the VOX gain

(0000=0% to 0255=100%)

17

0000 ~ 0255 Send/read the Anti VOX gain

(0000=0% to 0255=100%)

19

0000 ~ 0255 Send/read LCD backlight brightness

(0000=0% to 0255=100%)

15

*

1

01

00 or 01

Read noise or S-meter squelch status

(00=Close, 01=Open)

02

0000 to 0255 Read S-meter level

(0000=S0, 0120=S9, 0241=S9+60 dB)

05

00 or 01

Read various squelch (tone squelch, and so 

on) status

(00=Close, 01=Open)

07

00 or 01

Read the OVF status

( 00=OVF indicator is OFF, 01=OVF indicator is ON)

11

0000 ~ 0255 Read the PO meter level

(0000=0% to 0143=50% to 0213=100%)

 

D

Command table

NOTE: 

Operation of some control dials overrides CI-V commands. If a control dial, such as the AF Volume dial that  has 

a mark on it, is rotated after sending a CI-V command, the command will be overwritten by the operation.

Remote control

4

Summary of Contents for IC-9700

Page 1: ...CI V REFERENCE GUIDE 9700 VHF UHF ALL MODE TRANSCEIVER...

Page 2: ...Table of contents 1 1 Remote control 2 Remote control CI V information 2 D D CI V connection 2 D D Preparing 3 D D About the data format 3 D D Command table 4 D D Command formats 13...

Page 3: ...procedure on the web page may be changed without notice L Make the connection as short as possible The transceiver may not be recognized by the controller depending on the USB cable length The option...

Page 4: ...s Controller to IC 9700 IC 9700 to controller FE FE A2 E0 Cn Sc Data area FD Preamble code fixed Transceiver s default address Controller s default address Command number see the command table Sub com...

Page 5: ...g step 00 OFF 10 Hz or 1 Hz 01 100 Hz 02 500 Hz 03 1 kHz 04 5 kHz 05 6 25 kHz 06 10 kHz 07 12 5 kHz 08 20 kHz 09 25 kHz 10 50 kHz 11 100 kHz 11 00 Send read attenuator OFF setting 10 Send read 10 dB a...

Page 6: ...01 ON D D Command table Continued Cmd Sub cmd Data Description 17 3 See p 10 Send CW messages 18 00 Turn OFF the transceiver 01 4 Turn ON the transceiver 19 1 00 Read the transceiver ID 1A 00 See pp 1...

Page 7: ...SPEECH 00 OFF 01 ON 0055 00 or 01 SET Function SPEECH S Level SPEECH 00 OFF 01 ON D D Command table Continued Cmd Sub cmd Data Description 1A 05 0056 00 or 01 SET Function SPEECH MODE SPEECH 00 OFF 0...

Page 8: ...C 02 MIC ACC 03 USB 04 MIC USB 05 LAN Cmd Sub cmd Data Description 1A 05 0117 00 or 01 SET Connectors ACC SEND Output 144M 00 OFF 01 ON 0118 00 or 01 SET Connectors ACC SEND Output 430M 00 OFF 01 ON 0...

Page 9: ...Display RX Position Indicator 00 OFF 01 ON 0162 00 to 02 SET Display RX Position Display 00 OFF 01 ON Main Sub 02 ON Main Only Cmd Sub cmd Data Description 1A 05 0163 00 to 04 SET Display RX Position...

Page 10: ...Color Receive 0236 See p 16 RTTY DECODE SET Font Color Transmit 0237 00 or 01 RTTY DECODE LOG Decode Log 00 OFF 01 ON 0238 00 or 01 RTTY DECODE LOG Log Set File Type 00 Text 01 HTML D D Command table...

Page 11: ...00 to 09 GPS GPS TX Mode D PRS TX Format Object Gain 00 0 dB to 09 9 dB 0290 00 to 08 GPS GPS TX Mode D PRS TX Format Object Directivity 00 Omni 01 45 NE 02 90 E 03 135 SE 04 180 S 05 225 SW 06 270 W...

Page 12: ...monitor XFC 00 OFF 01 ON 03 1 See p 13 Read the transmit frequency Cmd Sub cmd Data Description 1E 00 1 Read number of available TX frequency band 01 1 See p 13 Read TX band edge frequencies 02 1 Read...

Page 13: ...N port regardless of those settings You cannot use the REMOTE terminal regardless of those settings Cmd Sub cmd Data Description 27 00 See p 24 Read the Scope waveform data Only when Scope ON OFF stat...

Page 14: ...digit 0 9 10 MHz digit 0 9 1 MHz digit 0 9 LOnly the 1200 MHz band can input 10 MHz digits Band edge frequency settings Command 02 1E 01 1E 03 q X X X w e r t y u i o 0 1 2 X X X X X X X X X 2 D X X X...

Page 15: ...selected and DUP can be set when other than DD mode is selected 4 Digital squelch setting X 0 4 0 Digital squelch function OFF 1 Digital call sign squelch function ON DSQL 2 Digital code squelch func...

Page 16: ...0202 Codes for character entries Command 1A 00 1A 05 0144 0151 0182 0259 0279 0281 0293 0316 1A 05 0262 1A 05 0265 1A 05 0268 1A 05 0271 Character codes Letters and Numbers Character ASCII code Chara...

Page 17: ...1A 05 0001 0004 0007 0010 0013 0014 X X X X The value of the HPF should be smaller than the LPF HPF Lower edge 00 Through 01 20 100 2000 Hz LPF Upper edge 05 24 500 2400 Hz 25 Through Color settings...

Page 18: ...mat y 1 Longitude ddd mm mmm format 2 5 Altitude 0 1 meter steps When reading the contents with no altitude sends 2 3 4 and 5 as FF When sending the contents with no altitude set 2 3 4 and 5 to FF Unp...

Page 19: ...h function OFF 1 Digital call sign squelch function ON DSQL 2 Digital code squelch function ON CSQL Fixed 3 5 Repeater tone frequency setting 6 8 Tone squelch frequency setting See Repeater tone tone...

Page 20: ...X X X X X X X X X X X o 2 q i q i Your own call sign setting 8 characters o 2 Note setting 4 characters DV TX call signs setting 24 characters Command 1F 01 Set UR R1 and R2 call signs of 8 character...

Page 21: ...e of the caller station 4 characters See Codes for character entries p 15 LFF When no call sign is received since the transceiver power was turned ON Example When a Gateway call is received RXRPT2 RXR...

Page 22: ...560 8 360 N 9 81 1561 5120 9 L The item that is not contained the received data is filled with FF LFF No signal has been received since the power was turned ON Object Command 20 03 0101 0201 X X X X X...

Page 23: ...e the power was turned ON Weather Command 20 03 0103 0203 X X X X X X X X X X 10 11 X X X X 12 16 X X X X 17 22 X X X X 23 29 30 31 32 0 3 X X X X 1 9 X X 33 X X X X 34 35 X X X X X X X X 39 40 41 42...

Page 24: ...cannot be set to 01 When VFO A is selected 00 frequency of VFO A changes 01 frequency of VFO B changes When VFO B is selected 00 frequency of VFO B changes 01 frequency of VFO A changes See Operating...

Page 25: ...ion 00 In range 01 Out of range If the scope data is out of range the waveform data u is omitted u Waveform data The transceiver outputs the drawn waveform data The data range or data length of the wa...

Page 26: ...kHz digit 0 9 10 MHz digit 0 9 1 MHz digit 0 9 1 GHz digit 0 1 100 MHz digit 0 4 10 Hz digit 0 9 1 Hz digit 0 9 1 kHz digit 0 9 100 Hz digit 0 9 100 kHz digit 0 9 10 kHz digit 0 9 10 MHz digit 0 9 1...

Page 27: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A7508 3EX 2019 Icom Inc Mar 2019...