96
14
CONTROL COMMAND
• Command table (continued)
Command
Sub command
Description
0E
A1–A7
Set
∂
F scan span (A1=±5 kHz,
A2=±10 kHz, A3=±20 kHz,
A4=±50 kHz, A5=±100 kHz,
A6=±500 kHz, A7=±1 MHz)
B0
Set as non-select channel
B1
Set as select channel
D0
Set scan resume OFF
D3
Set scan resume ON
0F
00
Turn the split function OFF
01
Turn the split function ON
10
Select simplex operation
11
Select –DUP operation
12
DUP operation
10
00
Select 10 Hz (1 Hz) tuning step
01
Select 100 Hz tuning step
02
Select 1 kHz tuning step
03
Select 5 kHz tuning step
04
Select 9 kHz tuning step
05
Select 10 kHz tuning step
06
Select 12.5 kHz tuning step
07
Select 20 kHz tuning step
08
Select 25 kHz tuning step
11
—
Select/read attenuator (0=OFF,
1=ON)
12
—
Select/read antenna selection
(0=ANT1, 1=ANT2)
13
00
Announce with voice synthesizer
01
(00=all data; 01=frequency and
02
S-meter level; 02=receive mode)
14
01 + Level data
[AF] level setting (0=max. CCW to
255=max. CW)
02 + Level data
[RF] level setting (0=max. CCW to
255=11 o’clock)
03 + Level data
[SQL] level setting (0=11 o’clock to
255=max. CW)
06 + Level data
[NR] level setting (0=min. to
255=max.)
07 + Level data
Inside [TWIN PBT] setting or IF
shift setting (0=max. CCW,
128=center, 255=max. CW)
08 + Level data
Outside [TWIN PBT] setting
(0=max. CCW, 128=center,
255=max. CW)
09 + Level data
[CW PITCH] setting (0=300 Hz,
128=600 Hz, 255=900 Hz)
0A + Level data
[RF PWR] setting (0=mini. to
255=max.)
0B + Level data
[MIC GAIN] setting (0=mini. to
255=max.)
0C + Level data [KEY SPEED] setting (0=slow to
255=fast)
0D + Level data [NOTCH] setting (0=low freq. to
255=high freq.)
0E + Level data
COMP Level Delay setting (0=0 to
10=10)
0F + Level data
Break-IN DELAY setting (20=2.0d
to 130=13.0d)
15
01
Read squelch condition
02
Read S-meter level
11
Read RF power meter
12
Read SWR meter
13
Read ALC meter
16
02
Preamp (0=OFF; 1=preamp 1;
2=preamp 2)
Command
Sub command
Description
16
12
AGC selection (0=OFF; 1=Slow;
2=Mid; 3=Fast)
22
Noise blanker (0=OFF; 1=ON)
40
Noise reduction (0=OFF; 1=ON)
41
Auto notch (0=OFF; 1=ON)
42
Repeater tone (0=OFF; 1=ON)
43
Tone squelch (0=OFF; 1=ON)
44
Speech compressor (0=OFF; 1=ON)
45
Monitor (0=OFF; 1=ON)
46
VOX function (0=OFF; 1=ON)
47
Break-in (0=OFF; 1=semi break-
in; 2=full break-in)
48
Manual notch (0=OFF; 1=ON)
49
RTTY filter (0=OFF; 1=ON)
4B
DTCS (0=OFF; 1=ON)
4C
VSC (0=OFF; 1=ON)
19
00
Read the transceiver ID
1A
00
Send/read memory contents (see
p. 97 for details)
01
Send/read band stacking register
contents (see p. 97 for details)
02
Send/read memory keyer con-
tents (see p. 97 for details)
03
Send/read the selected filter width
(0=50 Hz to 40/31=3600/2700 Hz)
04
Send/read the selected AGC time
constant (0=OFF, 1=0.1/0.3 sec. to
13=6.0/8.0 sec.)
0501
Send/read LCD contrast (0=0% to
255=100%)
0502
Send/read LCD backlight (0=0% to
255=100%)
0503
Send/read beep gain (0=min. to
255=max.)
0504
Send/read beep gain limit (0=OFF,
1=ON)
0505
Send/read calibration marker
(0=OFF, 1=ON)
0506
Send/read confirmation beep
(0=OFF, 1=ON)
0507
Send/read band edge beep
(0=OFF, 1=ON)
0508
Send/read RF/SQL control set
(0=Auto, 1=SQL, 2=RF+SQL)
0509
Send/read meter peak hold set
(0=OFF, 1=ON)
0510
Send/read COMP meter set
(0=OFF, 1=ON)
0511
Send/read quick split set (0=OFF,
1=ON)
0512
Send/read split offset –9.999 to
+9.999 MHz (see p. 98 for details)
0513
Send/read split lock set (0=OFF,
1=ON)
0514
Send/read duplex offset 0.000 to
9.999 MHz for HF (see p. 98 for
details)
0515
Send/read duplex offset 0.000 to
9.999 MHz for 50 MHz band (see
p. 98 for details)
0516
Send/read duplex offset 0.000 to
9.999 MHz for 144 MHz band
(see p. 98 for details)
IC-746PRO.qxd 02.4.2 11:32 Page 96
Summary of Contents for IC-746PRO
Page 115: ......