During [M-CH] acting as RIT control:
Rotate to shift the receive frequency.
• Rotate the control clockwise to increase the frequency, or rotate the control
counterclockwise to decrease the frequency.
• The shift frequency range is +/- 9.999 kHz in 1 Hz steps or +/- 9.99 kHz in 10 Hz
steps.
8. MANUAL NOTCH FILTER CONTROL [MNF]
(outer control)
Rotate to adjust the notch filter frequency to reject an interfering signal while the manual notch function is ON.
• The filter width can be set to narrow, middle or wide in the manual notch filter set mode accessed by push and hold the
button
for more than 1 Second. Push it again to exit notch filter set mode.
9. M-
CH/RIT•SET KEY
➥
Push to toggle the
[M-CH]
control activation between memory channel control and RIT control.
• The RIT function should be turned ON in advance.
• The RIT control indicator (6) lights orange when the
[M-CH]
control functions as the RIT control.
➥
Push and hold for 1 sec. to enter the quick set mode.
➥
During quick set mode, push and hold for 1 sec. to enter the set mode.
➥
During quick set mode or set mode, push to return to normal operation.
10. MODE KEY
➥
Push momentarily to cycle through the
operating modes:
USB/LSB
➟
CW/CW-R
➟
RTTY/RTTY-R
➟
AM
➥
Push and hold for 1 sec. to toggle the
following operating modes:
USB
↔
LSB; CW
↔
CW-R (Reverse);
RTTY
↔
RTTY-R (Reverse)
• “
CW-R
” or “
RTTY-R
” appears on the display when reverse mode is selected.N
ote: Unused modes can be inhibited in set mode.
11. TUNING STEP KEY
➥
Push to turn the programmable tuning step ON or OFF.
• “ ” appears above the 1 kHz indicator when the programmable tuning step is turned ON and the frequency can be changed in
programmed kHz steps.
➥
While the programmable tuning step is turned
ON (“ ” appears), push and hold for 1 sec. to enter tuning step set
mode; push again to return to normal operation.
• 0.1, 1, 5, 9 and 10 kHz programmable tuning steps
are available.
➥
While the programmable tuning step is turned OFF, push and hold for 1 sec. to turn the 1 Hz step ON and OFF.
• 1 Hz indication appears, and the frequency can be changed in 1 Hz steps.
12. REAMP/ATTENUATOR KEY
➥
Push to turn the preamp ON or OFF.
• “
” appears on the display.
➥
Push and hold for 1 sec. to turn the 20 dB attenuator ON; “
”
appears on the display.
• P
ush momentarily to turn the attenuator OFF.
13. MAIN DIAL [DIAL]
Changes the displayed frequency and selects values for selected set mode items, etc.
• About the
[M-CH]
control:
:ac