14*
09
0000 ~ 0255 Send/read CW pitch (5 Hz steps)
( 0000=300 Hz ~ 0128=600 Hz ~
0255=900 Hz)
0A
0000 ~ 0255 Send/read the selected band’s RF
power
(0000=Minimum ~ 0255=Maximum)
0B
0000 ~ 0255 Send/read MIC gain
(0000=Minimum ~ 0255=Maximum)
0C
0000 ~ 0255 Send/read keying speed
(0000=6 WPM ~ 0255=48 WPM)
0D
0000 ~ 0255 Send/read Notch filter setting
( 0000=max� Counter Clockwise ~
0128=center ~ 0255=max� Clockwise)
0E
0000 ~ 0255 Send/read the COMP level
(0000=0 ~ 0255=10)
0F
0000 ~ 0255 Send/read the Break-IN Delay setting
(0000=2�0d ~ 0255=13�0d)
12
0000 ~ 0255 Send/read NB level
(0000=0% ~ 0255=100%)
15
0000 ~ 0255 Send/read Monitor audio [MONI]
level
(0000=0% ~ 0255=100%)
16
0000 ~ 0255 Send/read the VOX gain
(0000=0% ~ 0255=100%)
17
0000 ~ 0255 Send/read the Anti VOX gain
(0000=0% ~ 0255=100%)
19
0000 ~ 0255 Send/read LCD backlight brightness
(0000=0% ~ 0255=100%)
15*
1
01
00/01
Read noise or S-meter squelch status
(00=Close, 01=Open)
02
0000 ~ 0255 Read S-meter level
( 0000=S0, 0120=S9,
0241=S9+60 dB)
05
00/01
Read various squelch (tone squelch,
and so on) status
(00=Close, 01=Open)
07
00/01
Read the OVF status
( 00=OVF indicator is OFF,
01=OVF indicator is ON)
11
0000 ~ 0255 Read the P
o
meter level
(0000=0% ~ 0143=50% ~ 0213=100%)
12
0000 ~ 0255 Read SWR meter level
( 0000=SWR1�0, 0048=SWR1�5,
0080=SWR2�0, 0120=SWR3�0)
13
0000 ~ 0255 Read ALC meter level
(0000=Minimum ~ 0120=Maximum)
14
0000 ~ 0255 Read COMP meter level
( 0000=0 dB ~ 0130=15 dB ~
0210=25�5 dB)
15
0000 ~ 0255 Read V
d
meter level
(0000=0 V ~ 0075=5 V ~ 0241=16 V)
16
0000 ~ 0255 Read I
d
meter level
(0000=0 A ~ 0121=2 A ~ 0241=4 A)
16*
02
00 ~ 02
Send/read the Preamp
( 00=OFF, 01=P�AMP1, 02=P�AMP2)
( In the 144 or 430 MHz bands,
00=OFF, 01=ON)
12
01 ~ 03
Send/read the AGC time constant
(01=FAST, 02=MID, 03=SLOW)
Remote control (CI-V) information
D
Command table
Cmd� Sub cmd�
Data
Description
16*
22
00/01
Send/read the Noise blanker
(00=OFF, 01=ON)
40
00/01
Send/read the Noise reduction
(00=OFF, 01=ON)
41
00/01
Send/read the Auto Notch function
(00=OFF, 01=ON)
42
00/01
Send/read the Repeater tone
(00=OFF, 01=ON)
43
00/01
Send/read the Tone squelch
(00=OFF, 01=ON)
44
00/01
Send/read the Speech compressor
(00=OFF, 01=ON)
45
00/01
Send/read the Monitor [MONI]
function
(00=OFF, 01=ON)
46
00/01
Send/read the VOX function
(00=OFF, 01=ON)
47
00 ~ 02
Send/read the BK-IN function
( 00=BK-IN OFF, 01=Semi BK-IN ON,
02=Full BK-IN ON)
48
00/01
Send/read the Manual Notch function
(00=OFF, 01=ON)
4B
00/01
Send/read the DTCS function
(00=OFF, 01=ON)
4F
00/01
Send/read the Twin peak filter
(00=OFF, 01=ON)
( Can be turned ON only when Mark
and Shift are set to 2125 Hz and
170 Hz, respectively)
50
00/01
Send/read the Dial lock function
(00=OFF, 01=ON)
56
00/01
Send/read DSP IF filter type in the
operating band
(00=SHARP, 01=SOFT)
57
00 ~ 02
Send/read the Manual Notch width
(00=WIDE, 01=MID, 02=NAR)
58
00 ~ 02
Send/read SSB transmit bandwidth
(00=WIDE, 01=MID, 02=NAR)
( One of following values is applied,
depending on the “COMP” status
(ON or OFF):
WIDE (Command: 1A 05 0017),
MID (Command: 1A 05 0018), or
NAR (Command: 1A 05 0019))
5B
00 ~ 02
Send/read the DSQL (Digital Call
Sign squelch)/CSQL (Digital Code
squelch) setting
(DV mode only)
(00=OFF, 01=DSQL, 02=CSQL)
5C
00 ~ 02
Send/read the GPS TX mode
(00=OFF, 01=D-PRS, 02=NMEA)
5D
00 ~ 03,
06 ~ 09
Send/read the Tone squelch function
( 00=OFF, 01=TONE, 02=TSQL,
03=DTCS, 06=DTCS (T),
07=TONE (T)/DTCS (R),
08=DTCS (T)/TSQL (R),
09=TONE (T)/TSQL (R))
17*
3
Send CW messages
18
00
Turn OFF the transceiver
01*
4
Turn ON the transceiver