21
6
SELCALL (Selective Calling)
6
7
10
15
18
8
13
11
16
9
14
12
17
1
4
2
5
3
■
Quiet mode
When the Quiet mode is turned ON, the Selcall Mute function is activated and allows
silent operation until receiving a Selcall.
1. Open the “Quiet Mode” screen.
[MENU] >
Quiet Mode
2. Select “On,” and then push [ENT] to turn ON the Quiet
mode.
•“Q” is displayed on the operating screen.
■
Stun
If the transceiver is in the Stun mode, it will request a password when you turn ON the
transceiver. This password is the same as the Power ON function password. Once the
correct password has been entered, the transceiver will not prompt you to enter it again.
Programming and transceiver operations are disabled after a Kill ID is received. By
activating the Program Write mode, you can use the transceiver again. (The internal data
cannot be accessed using the Program Read mode.)
To monitor the channel:
z
Hold down [MONI] for 2 seconds to release the mute
(audio is heard).
•The TX/RX indicator blinks green when the Monitor
function is activated.
To enable Selcall mute:
z
While the TX/RX indicator blinks green, hold down
[MONI] for 2 seconds to mute the channel.
•The TX/RX indicator stops blinking.
NOTE:
The Unmute mode may automatically return to the
Mute mode after a specified period of time, depending on
the presetting.