background image

877 757 8930 

[email protected] | www.icobath.com

Kontour Linear Towel Warmer Installation Guide 

Code: K4033E / K4034E / K4035E

24” x 40” Plug-In

INSTALLATION INSTRUCTIONS 

(see figure 1)

1.

  Fix wall supports “A” to the wall using the screws provided and in 

locations as shown on figure 2.

2.

    Hang and adjust the towel warmer using set screws “B” to lock stud “C” in 

the wall bracket “A”. Ensure the towel warmer is firmly and safely fixed.

PLUG-IN CONNECTION

TURN OFF POWER SUPPLY BEFORE PROCEEDING
Do not connect the towel warmer to the power supply until all instructions have been read and 
installation carried out in accord with them. Your towel warmer is 144W (110V) and conforms 
to CSA standards (File ref: 2422531). Please ensure the CSA label is visible.

1.

  Turn off power supply.

2.

 Plug connector in.

3.

 Turn on power supply.

1

2

3

ROUGH-IN REQUIREMENTS 

(see figure 2) 

1.

         Check  all  items have been received. 

1. 

Towel Warmer

2. 

Bracket Pack

2.

  Your towel warmer requires 110V GFCI protected power. This 110V receptacle should be located 

no further than 18” from the electric plug-in exit location on the towel warmer (see figure 2), and not 
above the electric plug-in exit location.

3.

  Wall studs or plywood backing is recommended in the wall at all bracket  

locations. See figure 2 for bracket locations.

Warning: In case of damage or failure of the towel warmer the unit should be returned to the manufacturer or their distributor. The 
warranty of 2 years on the towel warmer is NOT VALID in case of improper use or installation. Product is designed for use within Canada 
and the United States only.

FIGURE 1

a

c

b

Summary of Contents for KONTOUR K4033E

Page 1: ...2422531 Please ensure the CSA label is visible 1 Turn off power supply 2 Plug connector in 3 Turn on power supply 1 2 3 ROUGH IN REQUIREMENTS see figure 2 1 Check all items have been received 1 Towel Warmer 2 Bracket Pack 2 Your towel warmer requires 110V GFCI protected power This 110V receptacle should be located no further than 18 from the electric plug in exit location on the towel warmer see f...

Page 2: ... steel wool or other cleaning agents be used on this item Specifications Drawings Model Description Finish Weight lb Watts Volts WxH mm WxH Inches Metal Type K4033E Linear Electric Plug In Chrome 9 144W 110V 600 x 1000 23 5 x 39 25 Stainless Steel K4034E Linear Electric Plug In Brushed Nickel 9 144W 110V 600 x 1000 23 5 x 39 25 Stainless Steel K4035E Linear Electric Plug In Matte Black 9 144W 110V...

Page 3: ... l étiquette CSA 1 Couper le courant électrique 2 Brancher la fiche 3 Rétablir le courant électrique 1 2 3 REQUIS POUR L INSTALLATION voir la figure 2 1 Vérifier qu il ne manque aucune pièce 1 Sèche serviettes 2 Ensemble de montants de fixation 2 Le sèche serviettes nécessite un courant 110 V et un disjoncteur différentiel de fuite à la terre DDFT La prise 110 V devrait se trouver à 18 po au plus ...

Page 4: ...uces Type de métal K4033E Éléments d alimentation électrique Chrome 9 144W 110V 600 x 1000 23 5 x 39 25 Acier inoxydable K4034E Éléments d alimentation électrique Nickel Brossé 9 144W 110V 600 x 1000 23 5 x 39 25 Acier inoxydable K4035E Éléments d alimentation électrique Noir Mat 9 144W 110V 600 x 1000 23 5 x 39 25 Acier inoxydable FIGURE 2 877 757 8930 cs icobath com www icobath com Guide d insta...

Reviews: