ELECTRONIC CIRCULATOR FOR HEATING SYSTEMS - Art. P329

ICMA S.p.a. - Heating Technologies - www.icmaspa.it

FI.P329.EN.C  -  1 /2022

Icma SpA - Via Garavaglia, 4 - 20012 Cuggiono (MI) ITALY Tel: +39 02 97249134 - +39 02 97249135 - www.icmaspa.it - [email protected]

6

10. 

Any  modification  to  the  equipment  must  be  prior  agreed  upon  with  and 

authorized
by the manufacturer. Original spare parts and accessories authorized
by the manufacturer are integral part contributing to the safety of the equipment
and of the machines. The use of not original components or accessories
may endanger the safety and causes the termination of the warranty. A safe
operation is assured only for the applications and conditions described in 

 

3

Field of application

 of this manual. Non-observance of the safety instructions

results in the loss of any claims to damages.

Non-observance of the safety instructions results in the loss of any claims to

damages.

The indicated limit values are binding and cannot be exceeded for any reason
whatsoever.

3. FIELD OF APPLICATION

3.2 Pumped liquids

3.1 Types of system

Circulation of water/liquids in hot water heating systems and in renewable
energy solar thermal systems:
• One-pipe systems
• Two-pipe systems
• Systems with constant or variable flows
• Underfloor heating systems

• Boiler or primary circuit

• Storage tank circuit

Clean liquids, not aggressive and not explosive, not containing solid particles, fibers or mineral oils.

In heating systems:

• Water for heating according to VDI 2035;
• Mixtures of water and glycol with glycol percentages not greater than 30%.
In domestic hot water circulation systems, max. 38°d water hardness.

Any  other  use  is  regarded  as  incorrect  use.  For  the  use  with  other  fluids,  manufacturer’s  authorization  is 

required.

Keep these instructions for future reference.

• The circulators are not to be used to transfer flammable liquids such as gasoline, oils, gas oil 

or similar liquids.
• The circulators must never be used in refrigeration systems, air conditioning systems and 
similar installations.

Summary of Contents for P329

Page 1: ...20012 Cuggiono MI ITALY Tel 39 02 97249134 39 02 97249135 www icmaspa it sales icmaspa it 1 INSTALLATION AND OPERATION INSTRUCTIONS These instructions include information necessary to assemble and use...

Page 2: ...FIELD OF APPLICATION 6 3 1 Types of system 6 3 2 Pumped liquids 6 4 INSTALLATION AT SITE 8 4 1 Installation 8 4 2 Permissible installation positions 9 4 3 Motor housing positions 9 5 ELECTRIC CONNECT...

Page 3: ...rked by the symbol CAUTION electricity may endanger the safety of people as well as the integrity of things The inobservance of the safety provisions marked by the word CAUTION may endanger the integr...

Page 4: ...c safety precautions should be observed including the following 1 Read and follow all safety instructions and all the important notices on the appliance before installing using and maintaining the cir...

Page 5: ...all the circulator in an accessible place for future checks and disassembly procedures Foresee enough space for inspections and disassembling To avoid circulator overheating do not place any object on...

Page 6: ...damages The indicated limit values are binding and cannot be exceeded for any reason whatsoever 3 FIELD OF APPLICATION 3 2 Pumped liquids 3 1 Types of system Circulation of water liquids in hot water...

Page 7: ...4 20012 Cuggiono MI ITALY Tel 39 02 97249134 39 02 97249135 www icmaspa it sales icmaspa it 7 Ambient temperature Liquid temperature C Min C Max C 0 2 95 10 10 95 20 20 95 30 30 95 35 35 90 40 40 70 T...

Page 8: ...rocedures Foresee enough space for inspections and disassembling Foresee isolating valves at intake and output before and after the circulator to allow the disassembly without emptying the plant The a...

Page 9: ...4 3 Pay utmost care to prevent people from getting in contact with the hot surfaces of the circulator Drain the system or close the isolating valves on either side of the pump before the screws are re...

Page 10: ...voltage of the mains with the rating data All electric information concerning the A1 G413 is on the signaling plate The connection cord must be laid in such a way as it cannot come in contact with the...

Page 11: ...ivations deactivations through the mains voltage 20 24 h min 7 0 mm max 8 5 mm 6 COMMISSIONING 6 1 Start up of the circulator Absolutely avoid dry operation Start the circulator only after having comp...

Page 12: ...Operating elements 6 3 Mode of operation Fig 6 1 Selector and LED light LED COLOR DESCRIPTION Green P mode p v Proportional differential pressure The circulator head is proportionally reduced with dec...

Page 13: ...rapid succession of WHITE colour Following the light signal it s possible to easily vent the heating system as follows 1 Open the air vent valve in the hydraulic circuit above the circulator or open t...

Page 14: ...ing a flat screwdriver as given in the following table The selection of the right functioning curve depends on the characteristics of the heating system in question and the actual heat demand Factory...

Page 15: ...clean the impeller Loud noises of water circulation Flashing white LED Air in the system Vent the system 6 4 Automatic detection of the presence of air Vent system LED on The flow is too high Reduce t...

Page 16: ...t removed through the automatic release process after 100 attempts to restart the circulator it goes into standby and the LED remains red In this case follow the manual procedure described in the next...

Reviews: