9.
Status Indicator Light
(Lt 0 or 1)
0 = Status indicator never on
1 = Status indicator on with first stage
Press the or button to select.
Note:
Red light indicates heating cycle and green light indicates cooling cycle
Slide the
Mode
switch to
Heat
or
Cool
to exit configuration.
8.
Filter Check time
(300-800, – – –)
Set
Fan Run Time
(in hours) when
Check Filter
is displayed or set to – – – to disable.
Press the or button to select.
Note:
To reset filter counter to zero and clear filter warning, press the and
buttons simultaneously for 5 seconds.
Press the
SW6
button to advance to the next screen.
7.
Maximum heating or cooling cycles allowed per hour
(-, 2-6)
- = as many as needed, 2-6 = maximum cycles/hour
Press the or button to select.
Press the
SW6
button to advance to the next screen.
FILTER
SET
ROOM
SET
SET
SET
6.
Room temperature offset
(+9°F to -9°F) (+4.5°C to -4.5°C)
Adjust to calibrate displayed room temperature to match actual room temperature.
Note:
When not set to 0,
ROOM
will display
Press the or button to select.
Press the
SW6
button to advance to the next screen.
Summary of Contents for SimpleComfort 2010
Page 1: ......
Page 2: ......
Page 5: ... Parts Diagram ...
Page 20: ...This page left blank intentionally ...