Programming (continued)
• Set time is displayed
9. Press the or button to change set time.
10. Press the button to advance to the next screen.
Note:
Transitions required after 11:59 PM must be programmed in the next
day’s MORN period.
• Heat temperature is displayed (50°F to 90°F)
11. Press the or button to adjust heat set temperature.
12. Press the button to advance to the next screen.
• Cool temperature is displayed (45°F to 85°F)
13. Press the or button to adjust cool set temperature.
14. Press the button to advance to the next screen.
• Programmable fan is displayed
15. Press the or button to turn ON/OFF continuous indoor fan for that period.
16. Press the button to advance to the next screen.
Repeat steps 1-16 to program each day of the week individually or use the
Simpleset
®
feature (see Page 7) to program every day the same as Monday.
Press the button for 5 seconds to exit programming and return to the OFF mode.
Press the button to select the correct operating mode.
Press the button to enter and exit program mode. PROG displays when in program mode.