background image

Programming (continued)

• Set time is displayed

9.  Press the   or   button to change set time. 
10.  Press the   button to advance to the next screen.
 

 

Note:

  Transitions required after 11:59 PM must be programmed in the next 

day’s MORN period.

• Heat temperature is displayed (50°F to 90°F)

 

11.  Press the   or   button to adjust heat set temperature. 
12.  Press the   button to advance to the next screen.

• Cool temperature is displayed (45°F to 85°F)

 

13.  Press the   or   button to adjust cool set temperature.
14.  Press the   button to advance to the next screen.

• Programmable fan is displayed

 

15.  Press the   or   button to turn ON/OFF continuous indoor fan for that period.
16.  Press the   button to advance to the next screen.
Repeat steps 1-16 to program each day of the week individually or use the 
Simpleset

®

 feature (see Page 7) to program every day the same as Monday.

Press the   button for 5 seconds to exit programming and return to the OFF mode.

Press the   button to select the correct operating mode.

Press the   button to enter and exit program mode. PROG displays when in program mode.

Summary of Contents for SC 3801

Page 1: ...Changeover Simpleset 7 Day Programming Compatible with Gas Oil or Electric Title 24 Compliant No Batteries Required Relay Outputs minimum voltage drop in thermostat Ideally Suited for Residential New...

Page 2: ...erature decreases The thermostat will not let the compressor come on for four minutes after it turns off This protects your compressor The SC3801 has the following operating modes OFF Heat Emergency H...

Page 3: ...e delay for your compressor to restart after it has turned off Heat Mode In this mode the thermostat controls the heating system Note For heat pumps there is a four minute delay for your compressor to...

Page 4: ...return to the program schedule manually press the button twice The time and day of the week must be set for your program schedule to operate correctly 1 Verify thermostat is in non programmable mode u...

Page 5: ...ify thermostat is in non programmable mode use the button to exit prog mode 2 Press and release the button until OFF mode displays 3 Press the button for 6 seconds 4 Press the button twice Day is disp...

Page 6: ...3 Press the or button to adjust cool set temperature 14 Press the button to advance to the next screen Programmable fan is displayed 15 Press the or button to turn ON OFF continuous indoor fan for tha...

Page 7: ...day and make any changes you require This feature speeds up the programming of the standard weekday weekend schedule 3 Press button for 5 seconds to exit Program mode and return to the OFF mode Simple...

Page 8: ...85 F COOL 78 F COOL 82 F FAN ON OFF FAN ON OFF FAN ON OFF FAN ON OFF MONDAY thru SUNDAY Programmable fan option Factory Preprogramming Use the following personal program schedule to record your setti...

Page 9: ...L COOL FAN ON OFF FAN ON OFF FAN ON OFF FAN ON OFF TUESDAY 2 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL FAN ON OFF FAN ON OFF FAN ON OFF FAN ON OFF WEDNESDAY 3 MORN DAY EVE NITE HEAT HE...

Page 10: ...COOL COOL FAN ON OFF FAN ON OFF FAN ON OFF FAN ON OFF FRIDAY 5 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL FAN ON OFF FAN ON OFF FAN ON OFF FAN ON OFF SATURDAY 6 MORN DAY EVE NITE HEAT H...

Page 11: ...n Mode Page 19 in the Installation Operation and Application Guide Room temperature is not correct Verify wall hole is plugged with putty or insulation check wiring and location for remote sensor if u...

Page 12: ...r to permit the Seller to properly administer the warranty the Buyer shall 1 Notify the Seller promptly of any claim submitting date code information or any other pertinent data as requested by the Se...

Reviews: