background image

If your LCD is blank, or displaying 

LO BAT

, the batteries are not installed or need to be changed. We 

suggest you change the batteries at least once a year, or whenever the 

LO BAT 

warning displays. 

 

Note:

  After installing new batteries, you have to reset the room temperature setting and the 

differential setting. 

Step 1:

  Move the 

Cool/Off/Heat

 switch into the 

Off

 position.

Step 2:

  Move the 

Fan Auto/On

 switch into the 

Auto

 position.

Step 3:

  Remove the cover, and install the two “AA” alkaline batteries into the battery compartment. 

Proper battery installation is important! Make sure the positive ends of the batteries match the 

positive terminals in the battery compartment. 

If the display is on, the batteries are installed properly.

Installing and Changing Batteries

Replace the old labels with the enclosed new labels:

Replacing Wiring Labels

Old

New

Type

F, G

G

Fan control relay
Cool active reversing valve
Heat active reversing valve
Cooling control

H, W, 4

Heating control
Cooling transformer, hot side
Heat transformer, hot side

If the C terminal is the cooling control, connect to Y terminal; if it is the 

common side of the transformer, cap the wire and tuck into the wall

Summary of Contents for SC 2000

Page 1: ...tion on our complete range of American made products plus wiring diagrams troubleshooting tips and more visit us at www icmcontrols com Controls Single Stage Heating Cooling Systems Single Stage Heat...

Page 2: ...ting Thermostat 4 To Install Thermostat 4 Installing and Changing Batteries 6 Replacing Wiring Labels 6 Operation 7 A Quick Test 8 Wiring Diagrams 9 Troubleshooting 13 CAUTION This thermostat should b...

Page 3: ...witch Fan Switch Electric Gas Switch Battery Compartment Heat Pump Non Heat Pump Jumper Celsius Fahrenheit Jumper W RC RH Y B O G HEAT COOL OFF ON AUTO ELECTRIC GAS 2000 F C NON HP HP High Temperature...

Page 4: ...Temperature differential setting Room temperature Room temperature setpoint Always turn off the thermostat before installing removing cleaning or servicing turn off the power at the main power source...

Page 5: ...tems and heat pump systems works with gas oil or electric systems Compatible as a master thermostat in zoned system applications Freeze Protection Feature Protects pipes from freezing If the room temp...

Page 6: ...at base from wall 6 Refer to the following section for instructions on how to install this thermostat ELECTRICAL SHOCK HAZARD Turn off power at the main service panel by removing the fuse or switching...

Page 7: ...ng holes 9 Align thermostat base with mounting holes and feed the control wires through wire opening 10 Use supplied screws to mount thermostat base to wall CAUTION Be sure exposed portion of wires do...

Page 8: ...batteries into the battery compartment Proper battery installation is important Make sure the positive ends of the batteries match the positive terminals in the battery compartment If the display is...

Page 9: ...requently increase the temperature differential Step 1 Reset thermostat by removing batteries for 10 seconds Step 2 For the first 10 seconds of operation the temperature differential is displayed Pres...

Page 10: ...elay Action Set the Cool Off Heat switch to Heat Press the button until the temperature setting is 3 F above the room temperature Result The heating system and fan should turn on There may be a time d...

Page 11: ...ystem RH RC W Y B O G RH RC W Y B O G RH RC W Y B O G RH RC W Y B O G RH RC W Y B O G RH RC W Y B O G Zone 1 Zone 3 Zone 2 Zone 1 Zone 3 Zone 2 24 VAC 24 VAC Use appropriate size single pole double th...

Page 12: ...Cooling Control Fan Control T H E R M O S T A T RH RC W Y B O G HOT RH RC W Y B O G 120 VAC 24 VAC Remove Pre Installed Jumper Heating Control Cooling Control Fan Control Heating Transformer Cooling T...

Page 13: ...4 VAC Transformer Heating Control Fan Control T H E R M O S T A T RH RC W Y B O G Remove Pre Installed Jumper Heating Control T H E R M O S T A T RH RC W Y B O G Remove Pre Installed Jumper Thermopile...

Page 14: ...C Transformer Transformer HOT 120 VAC 24 VAC Transformer HOT 120 VAC 24 VAC Compressor Contactor Fan Relay Reversing Valve Compressor Contactor Fan Relay Reversing Valve Cooling Control Fan Control Co...

Page 15: ...that the fan switch setting matches your system gas or electric Thermostat is continuously turning on and off Increase the temperature differential see Setting a New Temperature Differential Page 7 Te...

Page 16: ...r to permit the Seller to properly administer the warranty the Buyer shall 1 Notify the Seller promptly of any claim submitting date code information or any other pertinent data as requested by the Se...