ICM Controls ICM2812ж ICM2812-KIT Installation, Operation & Application Manual Download Page 5

ICM2812 Cross Reference

Manufacturer

Part Number

Harness

Nordyne

710128A

2, 8 & 9

Rheem

695-200

2

 & 

4

See Note 2

Rheem/RUUD

62-22694-xx

2

 & 

4

Rheem/RUUD

62-22732-xx

2

 & 

4

Rheem/RUUD

62-24044-xx

2

 & 

4

Rheem/RUUD

62-24045-01

2

 & 

4

Rheem/RUUD

62-24046-01

2

 & 

4

Rheem/RUUD

62-24084-82

2

 & 

4

Rheem/RUUD

62-24268(-01,-02,-03)

2

 & 

4

Texas Instruments

41F-5

1 & 3

Texas Instruments

61F3

6

Texas Instruments

6DT(-1,-2)

6

Thermo Products

350486

6

Thermo Products

350836

6

Trane

D330927P01

6

See Note 1

Trane

D330930P01

6

Trane

D330934P01

6

Trane

D340035P01

6

Trane

D340774P01

6

Trane

D341213P01

6

Trane

D341396P01

6

United Technologies

1012-83-9336A

1 & 3

United Technologies

1012-83-9337A

1 & 3

United Technologies

1012-925(A,B,C)

2 & 4

United Technologies

1012-933D

1 & 3

Whirlpool

8068142

6

Whirlpool

8068561

6

Whirlpool

8068563

6

Whirlpool

99958174

6

Whirlpool

99958175

6

White-Rodgers

50A50-110

6

White-Rodgers

50A50-111

6

White-Rodgers

50A50-112

6

White-Rodgers

50A50-113

6

White-Rodgers

50A50-130

6

White-Rodgers

50A50-131

6

White-Rodgers

50A50-142

6

White-Rodgers

50A50-143

6

White-Rodgers

50A50-205

6

White-Rodgers

50A50-206

6

White-Rodgers

50A50-207

5 & 6

White-Rodgers

50A50-208

6

White-Rodgers

50A50-209

6

White-Rodgers

50A50-210

6

White-Rodgers

50A50-215

6

White-Rodgers

50A50-216

6

White-Rodgers

50A50-229

6

White-Rodgers

50A50-230

6

White-Rodgers

50A50-240

6

White-Rodgers

50A50-241

6

White-Rodgers

50A50-245

6

White-Rodgers

50A50-285

5 & 6

White-Rodgers

50A50-286

6

White-Rodgers

50A50-288

5 & 6

White-Rodgers

50A50-295

6

Manufacturer

Part Number

Harness

White-Rodgers

50A50-296

6

White-Rodgers

50A50-298

5 & 6

White-Rodgers

50A50-405

6

White-Rodgers

50A50-406

6

White-Rodgers

50A50-407

6

White-Rodgers

50A50-408

6

White-Rodgers

50A50-438

6

White-Rodgers

50A50-471

6

White-Rodgers

50A50-472

6

White-Rodgers

50A50-473

6

White-Rodgers

50A50-474

6

White-Rodgers

50A50-475

6

White-Rodgers

50A50-571

6

White-Rodgers

50A55-143

6

White-Rodgers

50A55-241

6

White-Rodgers

50A55-245

6

White-Rodgers

50A55-250

6

White-Rodgers

50A55-285

6

White-Rodgers

50A55-286

6

White-Rodgers

50A55-288

6

White-Rodgers

50A55-289

6

White-Rodgers

50A55-3797

6

White-Rodgers

50A55-438

6

White-Rodgers

50A55-474

6

White-Rodgers

50A55-476

6

White-Rodgers

50A55-480

6

White-Rodgers

50A55-486

6

White-Rodgers

50A55-571

6

White-Rodgers

50A55-743

5 & 6

White-Rodgers

50A55-843

6

White-Rodgers

50A56-242

6

White-Rodgers

50A56-243

6

White-Rodgers

50A56-956

6

White-Rodgers

50A65-120

6

White-Rodgers

50A65-121

6

White-Rodgers

50A65-143

6

White-Rodgers

50A65-288

6

White-Rodgers

50A65-289

6

White-Rodgers

50A65-474

6

White-Rodgers

50A65-475

6

White-Rodgers

50A65-476

6

White-Rodgers

50A65-5165

6

White-Rodgers

50A65-843

6

White-Rodgers

50A66-122

6

White-Rodgers

50A66-123

6

White-Rodgers

50A66-743

6

White-Rodgers

50M56-281

5 & 6

White-Rodgers

50M56-289

6

White-Rodgers

50M56-291

5 & 6

White-Rodgers

50M56-743

5

White-Rodgers

50T35-730

1, 3 & 7

White-Rodgers

50T35-743

1, 3 & 7

White-Rodgers

50T55-288

5 & 6

White-Rodgers

50T55-289

5 & 6

Summary of Contents for ICM2812ж ICM2812-KIT

Page 1: ...s application guide with the furnace installation manual for future reference Introduction Electrostatic Discharge ESD Precautions Use caution when installing and servicing the furnace to avoid and control electrostatic discharge ESD can impact electronic components These precautions must be followed to prevent electrostatic discharge from hand tools and personnel Following the precautions will pr...

Page 2: ...at wires and humidifier wires if equipped with a humidifier 6 Disconnect line voltage blower electronic air cleaner wires if equipped and transformer wires 7 Remove screws and any other fasteners and the old circuit board 8 Examine control and control box to check for water stains 9 Make repairs if any sources of water leakage are found Be sure to check humidifiers evaporator coils and vent system...

Page 3: ... igniter for proper operation input voltage check the transformer s common is grounded to earth ground 2 Pressure switch stuck closed Check for contaminated or defective pressure switch 3 Pressure switch stuck open Check for obstructed pressure switch tubing or defective pressure switch Check for oxidation on terminals broken wires or defective inducer motor 4 Limit switch fault Checked for blocke...

Page 4: ...Evcon Luxaire York 265901 6 Coleman Evcon Luxaire York 265902 6 Coleman Evcon Luxaire York 539617 6 Coleman Evcon Luxaire York 52537074000 6 Manufacturer Part Number Harness Coleman Evcon Luxaire York 52537077000 6 See Note 1 Coleman Evcon Luxaire York 031 00662 6 Coleman Evcon Luxaire York 031 00662 700 6 Coleman Evcon Luxaire York 031 01250 700 6 Coleman Evcon Luxaire York 031 01266 700 6 Colema...

Page 5: ...245 6 White Rodgers 50A50 285 5 6 White Rodgers 50A50 286 6 White Rodgers 50A50 288 5 6 White Rodgers 50A50 295 6 Manufacturer Part Number Harness White Rodgers 50A50 296 6 White Rodgers 50A50 298 5 6 White Rodgers 50A50 405 6 White Rodgers 50A50 406 6 White Rodgers 50A50 407 6 White Rodgers 50A50 408 6 White Rodgers 50A50 438 6 White Rodgers 50A50 471 6 White Rodgers 50A50 472 6 White Rodgers 50A...

Page 6: ...Surface Ignitor HSI 3 Inducer blower neutral 4 Hot Surface Ignitor HSI neutral Pressure Switches N O Note 1 For American Standard Trane York PCLU and York P3UR furnaces Install the black wire labeled 10 from pin 5 to pin 11 of the 12 pin harness which is connected to the furnace Note 2 There are some Rheem RUUD furnace models which performed flame sense differently Please read the information belo...