background image

11

Configuration and Thermostat Lock

During Configuration Mode, certain settings are protected by a  
numeric code access screen to prevent unintentional changes that  
could potentially damage the system or create a dangerous condition.

Whenever changes are attempted to one of the  
critical settings, the unlock code screen will appear:

The unlock code for these critical settings can be found during the  
power-up sequence. 

The large number (indicated by “98” in the diagram) is the code that  
will unlock the desired configuration setting.

The smaller numbers (indicated by “93” and “82” in the diagram) are  
codes used to lock and unlock your thermostat to prevent tampering.

To view the default codes for your thermostat, remove the thermostat from the sub base  
for 10 seconds. Reinstalling thermostat will cause the codes to display for approximately 5 seconds.

Write your 

codes here

Thermostat lock code

Configuration safety lock code

Locking & Unlocking Thermostat

Press 

, then 

, then 

MENU

LOCK

, then 

  

Use 

 & 

 to select digit.

Use 

 & 

 to set number.

Press 

 to lock or unlock.

LOCK

Enter Code

To lock and unlock thermostat, perform the following steps:

Summary of Contents for i3 2010WR

Page 1: ...Programmable Thermostat 7 Day 5 2 Day or 5 1 1 Day Programmable Configurable for Multiple Systems Large Display with Backlight Selectable Fahrenheit or Celsius Icon Indicator Lights Relay Outputs Min...

Page 2: ...on Drill with 3 16 bit hammer screwdriver Specifications Electrical Rating 24 VAC 18 30 VAC 1 amp maximum per output terminal 5 amp maximum total load Temperature Control Range 45 F to 90 F 7 C to 32...

Page 3: ...ressor come on for 4 minutes after it turns off to protect your compressor When the room temperature is greater than the set cool temperature by the differential temperature the cooling device is acti...

Page 4: ...and set vacation return dates Flashing The thermostat is in Setup Mode and is searching for a wireless network Flashing Wi Fi is busy Solid The thermostat is not connected to Wi Fi If the thermostat...

Page 5: ...screws to secure wires CAUTION Be sure exposed portion of wires do not touch other wires 9 Gently tug wire to be sure of proper connection Double check that each wire is connected to the proper termin...

Page 6: ...ps Y2 2nd stage cool for 2 compressor systems 2nd stage heat for 2 compressor heat pump systems G Fan W1 O B Configurable W1 1st stage heat for non heat pump systems O Cool active reversing valve B He...

Page 7: ...VAC Cool Compressor Heat 1 Reversing Valve y 2010WR Heating Cooling T H E R M O S T A T Sensor Common S1 SC S2 RH RC C Y1 W1 O B G W2 Optional Remote or Outdoor Sensors Heating Transformer 120 VAC Co...

Page 8: ...ressor 1 Cool Compressor 2 Heat 1 Reversing Valve 3020WR Heating Cooling T H E R M O S T A T Sensor Common S1 SC S2 RH RC C Y1 W1 O B G W2 Y2 Optional Remote or Outdoor Sensors Heating Transformer 120...

Page 9: ...e location for mounting the remote sensors 3 Mount the remote sensors using hardware provided 4 Install two strand shielded wire between the S1 terminal on the remote sensor and the S1 terminal on the...

Page 10: ...Output Chart 1ST Cool 2ND Cool 1ST Heat 2ND Heat 3RD Heat Heat Cool Y1 G YI Y2 G W1 G W1 W2 G W1 W2 AUX G Heat Pump One Compressor Y1 G O Y1 G O Y1 G B Y1 W2 G B Y1 W2 AUX G B Heat Pump Two Compresso...

Page 11: ...diagram is the code that will unlock the desired configuration setting The smaller numbers indicated by 93 and 82 in the diagram are codes used to lock and unlock your thermostat to prevent tampering...

Page 12: ...the previous screen Press the or to change settings within each screen Changes are saved automatically To exit configuration mode press Auto exit occurs after two minutes with no icons touched To chan...

Page 13: ...he or to set differential value Press to advance to the next screen CONFIG 3 2nd Stage Temperature Differential 1 F to 5 F 0 5 C to 2 5 C Note Not for 1010W Set the number of degrees between when stag...

Page 14: ...Heat Pump with 1 compressor and Cool Active Reversing Valve 6 Minimum Deadband 1 F to 9 F 1 C to 5 C Set the minimum separation between heat setpoint and cool setpoint in Auto Changeover Mode Press th...

Page 15: ...utdoor Temperature Setpoint Heat pump operation only Gas oil operation only F C Heat Pump with Gas Oil Back Up DF Heat Pump with Gas Oil Back Up DF Outdoor Temperature Setpoint Gas oil operation only...

Page 16: ...mode cannot be changed while the thermostat is locked Press the or to select Press to advance to the next screen CONFIG 10 Outdoor Lower Setpoint select to disable Appears only for heat pump with ele...

Page 17: ...CONFIG HEAT VACATION 15 Vacation Cooling Setpoint These work in conjunction with the Schedule mode where you set the date and time of your RETURN from vacation Page 28 Until that date time system will...

Page 18: ...ss to advance to the next screen 20 Fan Delay Off Time 0 30 60 90 seconds Select the amount of time the fan continues to operate after the cool heat demand has been satisfied Functions for cooling hea...

Page 19: ...e wireless network as if for the first time Note If the thermostat has been connected to a wireless network before the reset Wi Fi configuration will be the last screen in the Configuration Menu To ea...

Page 20: ...ack of the thermostat above the terminals and on the front of this book d Reset Wi Fi on thermostat To reset Wi Fi please follow the steps under Wi Fi Reset on Page 19 e Follow the prompts to connect...

Page 21: ...our Wireless Network a In the list of available networks select the correct network and enter password if password protected b will stop flashing and will display indicating the thermostat is successf...

Page 22: ...stration Press then press until displays Press to advance from one screen to the next Note Pressing will return you to the previous screen To exit weather press Setting the Time and Date 1 Press then...

Page 23: ...mode and press HEAT HEAT MODE The possible operating modes for the thermostat are OFF HEAT EM HEAT COOL and AUTO Use to select Auto Mode In this mode the thermostat controls either heating or cooling...

Page 24: ...s displayed 2 Adjust set temperature so it is 5 degrees below room temperature 3 Cooling should come on within a few seconds 4 Adjust the set temperature 2 degrees above the room temperature and the c...

Page 25: ...lect the minutes when you want the current period to begin 10 Press to continue 11 The HEAT temperature flashes Use the or to set the desired heat temperature 12 Press to continue 13 The COOL temperat...

Page 26: ...ed or unlocked View program schedule settings OFF shows when schedule is off SETTINGS show when schedule is on VIEW SCHEDULE SLEEP Mon View REMOTE SENSOR 1 temperature if not used VIEW Remote Sensor V...

Page 27: ...onth later To set the vacation timer and begin vacation setpoint mode 1 Press to select operating mode 2 Press then press until VACATION appears 3 Press to enter the date and time you plan to RETURN f...

Page 28: ...L COOL COOL WEDNESDAY 3 WAKE LEAVE RETURN SLEEP HEAT HEAT HEAT HEAT COOL COOL COOL COOL THURSDAY 4 WAKE LEAVE RETURN SLEEP HEAT HEAT HEAT HEAT COOL COOL COOL COOL MONDAY thru SUNDAY Factory Preprogram...

Page 29: ...ontinued FRIDAY 5 WAKE LEAVE RETURN SLEEP HEAT HEAT HEAT HEAT COOL COOL COOL COOL SATURDAY 6 WAKE LEAVE RETURN SLEEP HEAT HEAT HEAT HEAT COOL COOL COOL COOL SUNDAY 7 WAKE LEAVE RETURN SLEEP HEAT HEAT...

Page 30: ...minal connections LOCK displays when any button is pressed Thermostat has the button lockout function activated see Lockout Unlock Feature Page 11 on display instead of room temperature Check for a ba...

Page 31: ...may only operate using an antenna of a type and maximum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its ga...

Page 32: ...ect tampering improper storage incorrect installation or servicing not performed by the Seller In order to permit the Seller to properly administer the warranty the Buyer shall 1 Notify the Seller pro...