background image

FMX 400/FMX 700 SERIES USER MANUAL

6

Annual calibration to the thermal camera is recommended. Contact customer 

service to schedule maintenance.

2-2     Accuracy

For very accurate results, we recommend that you wait a minimum of 5 minutes 

after you have started the camera before measuring a temperature.

2-1     Calibration

2.

User Notice

2-4

     Disposal of Electronic Waste 

Electrical and electronic equipment (EEE) contains materials, components and 

substances that may be hazardous and present a risk to human health and 

the environment when waste electrical and electronic equipment (WEEE) is not 

handled correctly.

Equipment marked with the below crossed-out wheeled bin is electrical and 

electronic equipment. The crossed-out wheeled bin symbol indicates that 

waste electrical and electronic equipment should not be discarded together 

with unseparated household waste, but must be collected separately.

All local authorities have established collection schemes under which residents 

can dispose of equipment at a recycling center or other collection points, or 

WEEE will be collected directly from households. More detailed information is 

available from the administration of the relevant local authority. Always dispose 

of waste in accordance with local, state, and federal regulations.

2-3

     Cybersecurity

After the products are connected to the Internet, they may face risks including 

but not limited to network attacks, hacker attacks, virus infections, etc. The 

company will not be responsible for the abnormal operation of the products and 

any loss or liability caused therefrom shall be at your own risk.

Summary of Contents for FMX 400 Series

Page 1: ...UNIT ON IMPORTANT SAFETY INFORMATION INSIDE 2105 W Cardinal Dr Beaumont TX 77705 ICI cameras fall under US Federal Law and Export Control For more information contact us 409 861 0788 sales infraredcam...

Page 2: ...FMX 400 FMX 700 SERIES USER MANUAL 2 Revision History 11 2022 001 Document created...

Page 3: ...al Specifications 11 Structure 13 5 1 Appearance and Definitions of Housing Interface 13 Package Includes 14 Quick Start Instructions 15 7 1 Setup 15 7 2 Software Installation 17 Operation Instruction...

Page 4: ...ot showing camera s lagging or software crashing 25 11 2 Thermal imager shuts off unexpectedly 25 11 3 No thermal image 25 11 4 Camera out of focus 25 11 5 Unclear or dark visible images 26 11 6 Tempe...

Page 5: ...ten permission of Infrared Cameras Inc The documentation must not in whole or part be copied photocopied reproduced translated or transmitted to any electronic medium or machine readable form without...

Page 6: ...ent The crossed out wheeled bin symbol indicates that waste electrical and electronic equipment should not be discarded together with unseparated household waste but must be collected separately All l...

Page 7: ...of energy emitted from the first 1 1000th of an inch of a subject Environment of use industrial and petrochemical buildings electrical plants security rooms science labs animal reserves as well as en...

Page 8: ...FMX 400 FMX 700 SERIES USER MANUAL 8 2 9 Training To read about infrared training visit https infraredtraininginstitute com...

Page 9: ...er cord and do not place the device where the power cord can be easily touched Do not get water or salt water on the device or permit the device to get wet Damage to the device may occur Remove any wa...

Page 10: ...ED WITH THEIR CORRECT COVERS HATCHES OR CAPS THIS INCLUDES THE COMPARTMENTS FOR DATA STORAGE BATTERIES IF APPLICABLE AND CONNECTORS Do not put the product into a fire It is recommended to calibrate th...

Page 11: ...5 to 85 C 49 F to 185 F Detector Array UFPA VOx Pixel Pitch 17 m FOV 47 x 35 6 Focus Electronic Measurement Distance Lens dependent Spectral Band 8 m to 14 m Thermal Sensitivity NETD 40 mK 0 04 C at 3...

Page 12: ...12 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE FMX 400 P FMX 700 P Video Raw Emissivity Correction 0 01 to 1 0 IP Rating IP54 Internal non uniformit...

Page 13: ...00 SERIES USER MANUAL 13 5 1 Appearance and Definitions of Housing Interface 5 Structure 1 Germanium Lens 2 LED Indicator Light 3 Power Interface 4 Data Interface 5 RJ 45 Internet access 6 Reset Butto...

Page 14: ...00 SERIES USER MANUAL 14 6 Package Includes ENSURE ALL SYSTEM EQUIPMENT AND COMPONENT ITEMS ARE PRESENT BEFORE BEGINNING INSTALLATION Coaxial Cable Power Adapter Ethernet Cable FMX Series device Softw...

Page 15: ...ctions MAKE SURE TRIPODS DO NOT BLOCK THE DIRECT PATH OF PERSON S TO BE IMAGED TO ENSURE THE EQUIPMENT WILL NOT BE MOVED OR KNOCKED DOWN USING A DIVIDING BARRIER WILL HELP KEEP TRIPODS SEPARATE FROM T...

Page 16: ...end of coaxial cable B C Plug Ethernet cable into the Ethernet port of the FMX Series device Plug the other end of the Ethernet cable into the Ethernet port of the computer ENSURE THE CAMERA LENS AND...

Page 17: ...T 10 MINUTES FOR THE DEVICE TO ACCLIMATE THIS WILL PROVIDE THE MOST ACCURATE TEMPERATURE MEASUREMENTS 7 2 Software Installation A B Install IR Flash software using the software USB drive Refer to the...

Page 18: ...d to set a gateway as this is a direct connection from the computer to the cameras with no router Be sure the static IP address is set by doing the following 1 Click on Windows icon 2 Click on Setting...

Page 19: ...h Pro web page under the Downloads section or at this address https infraredcameras com ir flash pro manual Processor Intel i5 Quad core or above RAM 4 GB or above OS Windows 8 8 1 10 Hard Drive 256 G...

Page 20: ...ean replace the cloth and repeat the wiping process 9 2 Disinfecting the Camera Surface Do not use corrosive cleaning solutions on the optical glass components It is recommended to disinfect the camer...

Page 21: ...tomer service if there is an issue IF YOUR PACKAGE INCLUDES ADDITIONAL LENSES A SEPARATE CALIBRATION IS REQUIRED FOR EACH LENS CONTACT CUSTOMER SERVICE IS THERE IS AN ISSUE 10 2 Radiometry Correction...

Page 22: ...is To set the emissivity enter a value from 0 01 to 1 0 in the input box The accompanying table gives the typical emissivity of important materials Material Emissivity Water 96 Stainless steel 14 Alum...

Page 23: ...over water there may be no perceived thermal difference between the horizon and the water i e the horizon can seem to disappear Users can change their angle by changing where they stand or by attachin...

Page 24: ...the screen plots image information in the form of a histogram or a 3D rendering It also allows users to visualize the temperature data over time for any all ROIs placed on the image the last image bel...

Page 25: ...t mask of 255 255 255 0 Restart computer Verify that correct software is installed Uninstall reinstall software running as administrator Verify that firewall is not blocking software Try newer or diff...

Page 26: ...incorrect Turn off the device then turn it back on Ensure the device has sufficiently acclimated to the environment before taking measurements Device is at proper height Ensure device is in focus Adj...

Page 27: ...engineers scientists inspectors and operators in space power companies medical pulp and paper food industry research and development and various process industries You can see our products and servic...